RECONSTRUCT study protocol for real-world outcomes of covered endovascular reconstruction of the aortic bifurcation using the GORE VIABAHN VBX balloon-expandable endoprosthesis to treat aortoiliac occlusive disease

<h2>Abstract</h2><h3>Objective</h3> Aortoiliac occlusive disease (AIOD) is a common manifestation of peripheral artery disease (PAD), and contributes substantially to global morbidity and mortality. Although open surgical repair provides durable outcomes, its risks have led to a shift toward endovascular-first strategies. The covered endovascular reconstruction of the aortic bifurcation (CERAB) technique has emerged as a promising option for complex AIOD. The objective of this manuscript is to describe the methodology of the RECONTSRUCT study, designed to evaluate the safety and effectiveness of the GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis (VBX Stent Graft) in the CERAB procedure for AIOD. <h3>Methods</h3> The RECONSTRUCT study is a multicenter, single-arm, retrospective study enrolling at least 158 patients across 35 sites in the United States and Europe. Data collection includes demographics, medical history, procedural details, device characteristics, and clinical follow-up from electronic health records. The primary effectiveness endpoint is 1-year primary patency, defined as uninterrupted blood flow (<50% binary restenosis) through the CERAB devices without target lesion revascularization (TLR). The primary safety endpoint is 30-day morbidity, defined as any major adverse cardiovascular event or procedure related reintervention. Secondary endpoints include technical success, 30-day mortality, freedom from device fracture, primary assisted and secondary patency, freedom from TLR and clinically-driven TLR, and overall survival. <h3>Conclusion</h3> The study will provide real-world, multicenter evidence on VBX stent graft use in CERAB for AIOD. Standardized data collection with independent review and adjudication will enhance data reliability, and findings may address an important evidence gap in managing complex aortoiliac disease.

Institutions

Publication Details

Journal
JVS-Vascular Insights
Published
2025-12-17
DOI
https://doi.org/10.1016/j.jvsvi.2025.100342
Primary Topic
Peripheral Artery Disease Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

RECONSTRUCT study protocol for real-world outcomes of covered endovascular reconstruction of the aortic bifurcation using the GORE VIABAHN VBX balloon-expandable endoprosthesis to treat aortoiliac occlusive disease

JVS-Vascular Insights
Peripheral Artery Disease Management
article

RECONSTRUCT study protocol for real-world outcomes of covered endovascular reconstruction of the aortic bifurcation using the GORE VIABAHN VBX balloon-expandable endoprosthesis to treat aortoiliac occlusive disease

article en

Abstract

<h2>Abstract</h2><h3>Objective</h3> Aortoiliac occlusive disease (AIOD) is a common manifestation of peripheral artery disease (PAD), and contributes substantially to global morbidity and mortality. Although open surgical repair provides durable outcomes, its risks have led to a shift toward endovascular-first strategies. The covered endovascular reconstruction of the aortic bifurcation (CERAB) technique has emerged as a promising option for complex AIOD. The objective of this manuscript is to describe the methodology of the RECONTSRUCT study, designed to evaluate the safety and effectiveness of the GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis (VBX Stent Graft) in the CERAB procedure for AIOD. <h3>Methods</h3> The RECONSTRUCT study is a multicenter, single-arm, retrospective study enrolling at least 158 patients across 35 sites in the United States and Europe. Data collection includes demographics, medical history, procedural details, device characteristics, and clinical follow-up from electronic health records. The primary effectiveness endpoint is 1-year primary patency, defined as uninterrupted blood flow (<50% binary restenosis) through the CERAB devices without target lesion revascularization (TLR). The primary safety endpoint is 30-day morbidity, defined as any major adverse cardiovascular event or procedure related reintervention. Secondary endpoints include technical success, 30-day mortality, freedom from device fracture, primary assisted and secondary patency, freedom from TLR and clinically-driven TLR, and overall survival. <h3>Conclusion</h3> The study will provide real-world, multicenter evidence on VBX stent graft use in CERAB for AIOD. Standardized data collection with independent review and adjudication will enhance data reliability, and findings may address an important evidence gap in managing complex aortoiliac disease.

JVS-Vascular InsightsVol. 4
University of Padua (IT), University of South Florida (US), W. L. Gore & Associates (United States) (US), California State University, Fresno (US)
Good health and well-being
Openalex Percentile: Top 28%
Peripheral Artery Disease Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.