Influencia del diseño de la sección transversal sobre la resistencia a la fatiga cíclica de dos instrumentos endodónticos de Níquel- Titanio en canales artificiales con Curvatura de 60°: Estudio In Vitro

Abstract The unexpected fracture of nickel-titanium rotating instruments (NiTi) during endodontic treatments represents a critical complication, especially in curved ducts where cyclic fatigue constitutes one of the main causes of failure. This situation has motivated the search for improvements in the geometric design of the instruments, particularly in the cross-section, to increase their resistance and clinical safety. This research aims to evaluate the influence of the cross-sectional design of two Nickel Titanium endodontic instruments on the resistance to cyclic fatigue using artificial ducts with a curvature of sixty degrees, by measuring the time it takes the instrument to break. A comparative and cross-sectional in vitro investigation was carried out with 40 files categorized into two groups: AF™ F-One ("S" section) and JIZAI (rectangular eccentric section). Each instrument was subjected to continuous rotation at 500RPM under standardized circumstances until its breakage, with measurements taken for the number of cycles and the duration in seconds. The findings indicated that the JIZAI file exhibited an average of 2238.33 cycles to fracture and an average duration of 268.6 seconds, while the AF™ F-One demonstrated 787.83 cycles and 94.47 seconds. The differences were statistically substantial (p < 0.001), demonstrating the best performance of the JIZAI system. This benefit is attributed to its optimized geometric configuration and sophisticated thermal processing, which provide a more effective distribution of internal stresses, identifying that JIZAI demonstrated superior resistance to cyclic fatigue, which makes it a safer and more effective option for instrumentation in curved channels.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-07-30
DOI
https://doi.org/10.5281/zenodo.17936449
Primary Topic
Endodontics and Root Canal Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influencia del diseño de la sección transversal sobre la resistencia a la fatiga cíclica de dos instrumentos endodónticos de Níquel- Titanio en canales artificiales con Curvatura de 60°: Estudio In Vitro

Zenodo (CERN European Organization for Nuclear Research)
Endodontics and Root Canal Treatments
article

Influencia del diseño de la sección transversal sobre la resistencia a la fatiga cíclica de dos instrumentos endodónticos de Níquel- Titanio en canales artificiales con Curvatura de 60°: Estudio In Vitro

article en

Abstract

Abstract The unexpected fracture of nickel-titanium rotating instruments (NiTi) during endodontic treatments represents a critical complication, especially in curved ducts where cyclic fatigue constitutes one of the main causes of failure. This situation has motivated the search for improvements in the geometric design of the instruments, particularly in the cross-section, to increase their resistance and clinical safety. This research aims to evaluate the influence of the cross-sectional design of two Nickel Titanium endodontic instruments on the resistance to cyclic fatigue using artificial ducts with a curvature of sixty degrees, by measuring the time it takes the instrument to break. A comparative and cross-sectional in vitro investigation was carried out with 40 files categorized into two groups: AF™ F-One ("S" section) and JIZAI (rectangular eccentric section). Each instrument was subjected to continuous rotation at 500RPM under standardized circumstances until its breakage, with measurements taken for the number of cycles and the duration in seconds. The findings indicated that the JIZAI file exhibited an average of 2238.33 cycles to fracture and an average duration of 268.6 seconds, while the AF™ F-One demonstrated 787.83 cycles and 94.47 seconds. The differences were statistically substantial (p < 0.001), demonstrating the best performance of the JIZAI system. This benefit is attributed to its optimized geometric configuration and sophisticated thermal processing, which provide a more effective distribution of internal stresses, identifying that JIZAI demonstrated superior resistance to cyclic fatigue, which makes it a safer and more effective option for instrumentation in curved channels.

Zenodo (CERN European Organization for Nuclear Research)
International Association for Dental Research (US)
Openalex Percentile: Top 31%
Endodontics and Root Canal Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.