Experimental investigation on the racking resistance of cold-formed steel wall panels sheathed with fibre-cement boards

This paper presents an experimental investigation on the racking resistance of cold-formed steel (CFS) framed wall panels sheathed with fibre-cement boards (FCB) under monotonic loads. Three full-scale wall panel specimens were fabricated and tested to investigate the influence of the fixing type and frame assembly on the racking resistance. The test program includes specimens assembled using different screw types and stud arrangements at the joint between the two fibre-cement boards. The racking (shear) strength, stiffness and ductility of the test specimens were measured. The results show that the use of non-winged fixings significantly increases the ductility and stiffness of the wall panel. The failure modes observed were characterised by simultaneous board cracking and tilting of the fixings, with no significant plastic deformation occurred on the steel frame.

Institutions

Publication Details

Journal
Edinburgh Research Explorer (University of Edinburgh)
Published
2024-12-11
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental investigation on the racking resistance of cold-formed steel wall panels sheathed with fibre-cement boards

Edinburgh Research Explorer (University of Edinburgh)
Structural Load-Bearing Analysis
article

Experimental investigation on the racking resistance of cold-formed steel wall panels sheathed with fibre-cement boards

article en

Abstract

This paper presents an experimental investigation on the racking resistance of cold-formed steel (CFS) framed wall panels sheathed with fibre-cement boards (FCB) under monotonic loads. Three full-scale wall panel specimens were fabricated and tested to investigate the influence of the fixing type and frame assembly on the racking resistance. The test program includes specimens assembled using different screw types and stud arrangements at the joint between the two fibre-cement boards. The racking (shear) strength, stiffness and ductility of the test specimens were measured. The results show that the use of non-winged fixings significantly increases the ductility and stiffness of the wall panel. The failure modes observed were characterised by simultaneous board cracking and tilting of the fixings, with no significant plastic deformation occurred on the steel frame.

Edinburgh Research Explorer (University of Edinburgh)
Steel Construction Institute (GB)
Edinburgh Napier University
Sustainable cities and communities
Openalex Percentile: Top 53%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.