Proposed Typical Diagnostic reference levels in paediatric radiography exams

The aim of this project is to study the doses delivered to children undergoing radiographic examinations in the radiology department of the mother and child hospital of the Mohammed VI University Hospital Centre in Marrakech (MCH- Med VI UHC-M), and to establish the typical diagnostic reference levels (TDRL) specific to these exams. The dosimetric data obtained were compared with the published literature. This study involved 1080 radiographs of children divided into three age groups: 1 year to 5 years G1-5 years (n=360), 5 to 10 years G5-10 years (n=360) and 10 to 15 years G10-15 years (n=360). Six radiographic examinations were selected: Chest X-ray anterior-posterior (AP), pelvis X-ray (AP), skull X-ray (AP), abdomen X-ray (ASP) (AP), leg X-ray (AP) and lateral (LAT) and forearm X-ray (AP/LAT). Each with standard clinical indications. For analysis, Median values of entrance skin dose ESD (mGy) were evaluated using MICADO software. In one hand, the outcomes showed that the TDRL in terms of ESD (mGy) for chest X-rays for children was higher than the national diagnostic reference levels observed internationally, but on the other hand, the TDRLs of abdomen, pelvis, and skull X-ray examinations were lower.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-09-09
DOI
https://doi.org/10.1051/radiopro/2025032/pdf
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Proposed Typical Diagnostic reference levels in paediatric radiography exams

Springer Link (Chiba Institute of Technology)
Radiation Dose and Imaging
article

Proposed Typical Diagnostic reference levels in paediatric radiography exams

article en

Abstract

The aim of this project is to study the doses delivered to children undergoing radiographic examinations in the radiology department of the mother and child hospital of the Mohammed VI University Hospital Centre in Marrakech (MCH- Med VI UHC-M), and to establish the typical diagnostic reference levels (TDRL) specific to these exams. The dosimetric data obtained were compared with the published literature. This study involved 1080 radiographs of children divided into three age groups: 1 year to 5 years G1-5 years (n=360), 5 to 10 years G5-10 years (n=360) and 10 to 15 years G10-15 years (n=360). Six radiographic examinations were selected: Chest X-ray anterior-posterior (AP), pelvis X-ray (AP), skull X-ray (AP), abdomen X-ray (ASP) (AP), leg X-ray (AP) and lateral (LAT) and forearm X-ray (AP/LAT). Each with standard clinical indications. For analysis, Median values of entrance skin dose ESD (mGy) were evaluated using MICADO software. In one hand, the outcomes showed that the TDRL in terms of ESD (mGy) for chest X-rays for children was higher than the national diagnostic reference levels observed internationally, but on the other hand, the TDRLs of abdomen, pelvis, and skull X-ray examinations were lower.

Springer Link (Chiba Institute of Technology)
Openalex Percentile: Top 32%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Proposed Typical Diagnostic reference levels in paediatric radiography exams · Springer Link (Chiba Institute of Technology) (2025) | TGRS Research Map | TGRS