Analytical study on the seismic behavior of cracked masonry house walls retrofitted with ferrocement layer

This study numerically evaluates the seismic performance of a cracked wall element from a 1:4 scaled RM house model using ETABS v.22. The model is first analyzed without strengthening under time-history earthquake loads of 0.3 g, 0.6 g, and 1.0 g. Cracking occurred at 1.0 g when the maximum tensile stress reached 0.50 MPa, exceeding the allowable limit of 0.264 MPa. A strengthening approach using a 10 cm wide ferrocement layer applied on both sides of the cracked region is then examined, reducing the tensile stress to 0.33 MPa, although it remains above the allowable value. With the addition of a 5 mm plaster coating on both faces of the strengthened area, the wall tensile stress further decreases to 0.21 MPa, indicating that structural performance has been restored to a safe level below the critical threshold. These results confirm that the combined ferrocement and plaster strengthening system is effective in enhancing the seismic resistance of cracked RM walls in non-engineered residential buildings, thus supporting safer post-earthquake rehabilitation and continued occupancy.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-12-12
DOI
https://doi.org/10.1051/e3sconf/202567707001/pdf
Primary Topic
Masonry and Concrete Structural Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analytical study on the seismic behavior of cracked masonry house walls retrofitted with ferrocement layer

Springer Link (Chiba Institute of Technology)
Masonry and Concrete Structural Analysis
article

Analytical study on the seismic behavior of cracked masonry house walls retrofitted with ferrocement layer

article en

Abstract

This study numerically evaluates the seismic performance of a cracked wall element from a 1:4 scaled RM house model using ETABS v.22. The model is first analyzed without strengthening under time-history earthquake loads of 0.3 g, 0.6 g, and 1.0 g. Cracking occurred at 1.0 g when the maximum tensile stress reached 0.50 MPa, exceeding the allowable limit of 0.264 MPa. A strengthening approach using a 10 cm wide ferrocement layer applied on both sides of the cracked region is then examined, reducing the tensile stress to 0.33 MPa, although it remains above the allowable value. With the addition of a 5 mm plaster coating on both faces of the strengthened area, the wall tensile stress further decreases to 0.21 MPa, indicating that structural performance has been restored to a safe level below the critical threshold. These results confirm that the combined ferrocement and plaster strengthening system is effective in enhancing the seismic resistance of cracked RM walls in non-engineered residential buildings, thus supporting safer post-earthquake rehabilitation and continued occupancy.

Springer Link (Chiba Institute of Technology)
Sustainable cities and communities
Openalex Percentile: Top 44%
Masonry and Concrete Structural Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.