Evaluation of ECG Waveform Accuracy in the CardioBAN Wearable Device: An Initial Analysis

This study evaluates the morphological performance of the CardioBAN wearable electrocardiogram (ECG) device by comparing its beat-level waveform accuracy against a clinically certified reference system (GE Vivid E9). A cycle-by-cycle Dynamic Time Warping (DTW) analysis was employed to assess beat-level waveform similarity between both devices in 17 healthy participants under controlled conditions. Each cardiac cycle from CardioBAN was aligned to its reference counterpart, enabling a fine-grained comparison of waveform shape. The resulting DTW distances (mean 0.493 ± 0.166) demonstrated overall high morphological agreement, with lower values occurring in recordings with stable beat morphology and higher values primarily reflecting normal variability related to minor motion artifacts or electrode–skin impedance fluctuations. A complementary Bland–Altman analysis of point-wise amplitude differences after DTW alignment showed minimal bias (0.079) and narrow limits of agreement (−0.897–1.055), confirming strong amplitude concordance between systems. These findings indicate that the CardioBAN wearable reliably reproduces key ECG morphological features under controlled, short-term recording conditions. Further studies encompassing ambulatory environments and clinical populations are needed to evaluate its suitability for real-world and pathological scenarios.

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-12-14
DOI
https://doi.org/10.3390/app152413143
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of ECG Waveform Accuracy in the CardioBAN Wearable Device: An Initial Analysis

Applied Sciences
ECG Monitoring and Analysis
article

Evaluation of ECG Waveform Accuracy in the CardioBAN Wearable Device: An Initial Analysis

article en

Abstract

This study evaluates the morphological performance of the CardioBAN wearable electrocardiogram (ECG) device by comparing its beat-level waveform accuracy against a clinically certified reference system (GE Vivid E9). A cycle-by-cycle Dynamic Time Warping (DTW) analysis was employed to assess beat-level waveform similarity between both devices in 17 healthy participants under controlled conditions. Each cardiac cycle from CardioBAN was aligned to its reference counterpart, enabling a fine-grained comparison of waveform shape. The resulting DTW distances (mean 0.493 ± 0.166) demonstrated overall high morphological agreement, with lower values occurring in recordings with stable beat morphology and higher values primarily reflecting normal variability related to minor motion artifacts or electrode–skin impedance fluctuations. A complementary Bland–Altman analysis of point-wise amplitude differences after DTW alignment showed minimal bias (0.079) and narrow limits of agreement (−0.897–1.055), confirming strong amplitude concordance between systems. These findings indicate that the CardioBAN wearable reliably reproduces key ECG morphological features under controlled, short-term recording conditions. Further studies encompassing ambulatory environments and clinical populations are needed to evaluate its suitability for real-world and pathological scenarios.

Applied SciencesVol. 15(24)
Universidade Politécnica do Cávado e do Ave (PT), Universidade de Santiago de Compostela (ES), Centro de Computação Gráfica (PT), University of Minho (PT)
Openalex Percentile: Top 32%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.