Comparison of The Accuracy in Working Length of Electronic Foraminal Locators After Cervical Preflaring: An in Vitro Study

Abstract To evaluate the influence of cervical preflaring on the accuracy of working length determination using electronic foraminal locators. Forty single-rooted premolars classified as Vertucci type I were used to analyze the accuracy of three electronic foraminal locators (Root ZX Mini, Raypex 6, and Minipex). The actual working length was determined visually under a microscope, and the electronic measurements were performed in alginate. These measurements were recorded both before and after cervical preflaring. The preflaring was performed using an ORIFICE SHAPER (ONE FLARE) at 400 RPM and 3 N, with irrigation using 5.25% sodium hypochlorite. The purpose was to evaluate the effect of preflaring on the accuracy of electronic foraminal locators. The results showed significant differences in working length measurements before and after cervical preflaring. The accuracy of Raypex 6 and Minipex was affected, but not that of the Root ZX mini. Raypex 6 and Minipex improved their precision after cervical preflaring. Root ZX mini was more accurate before preflaring, although Raypex 6 surpassed it afterward. The accuracy of electronic foraminal locators varies depending on the method used. This research concludes that cervical preflaring affects the accuracy of the studied foraminal locators differently. Raypex 6 and Minipex improved their accuracy with cervical preflaring, while Root ZX mini consistently maintained its precision. These results suggest that the advantage of cervical preflaring depends on the locator used and is more beneficial for devices whose accuracy improves after its application.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-07-30
DOI
https://doi.org/10.5281/zenodo.17920761
Primary Topic
Endodontics and Root Canal Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of The Accuracy in Working Length of Electronic Foraminal Locators After Cervical Preflaring: An in Vitro Study

Zenodo (CERN European Organization for Nuclear Research)
Endodontics and Root Canal Treatments
article

Comparison of The Accuracy in Working Length of Electronic Foraminal Locators After Cervical Preflaring: An in Vitro Study

article en

Abstract

Abstract To evaluate the influence of cervical preflaring on the accuracy of working length determination using electronic foraminal locators. Forty single-rooted premolars classified as Vertucci type I were used to analyze the accuracy of three electronic foraminal locators (Root ZX Mini, Raypex 6, and Minipex). The actual working length was determined visually under a microscope, and the electronic measurements were performed in alginate. These measurements were recorded both before and after cervical preflaring. The preflaring was performed using an ORIFICE SHAPER (ONE FLARE) at 400 RPM and 3 N, with irrigation using 5.25% sodium hypochlorite. The purpose was to evaluate the effect of preflaring on the accuracy of electronic foraminal locators. The results showed significant differences in working length measurements before and after cervical preflaring. The accuracy of Raypex 6 and Minipex was affected, but not that of the Root ZX mini. Raypex 6 and Minipex improved their precision after cervical preflaring. Root ZX mini was more accurate before preflaring, although Raypex 6 surpassed it afterward. The accuracy of electronic foraminal locators varies depending on the method used. This research concludes that cervical preflaring affects the accuracy of the studied foraminal locators differently. Raypex 6 and Minipex improved their accuracy with cervical preflaring, while Root ZX mini consistently maintained its precision. These results suggest that the advantage of cervical preflaring depends on the locator used and is more beneficial for devices whose accuracy improves after its application.

Zenodo (CERN European Organization for Nuclear Research)
International Association for Dental Research (US)
Openalex Percentile: Top 32%
Endodontics and Root Canal Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.