Adaptive Constant Current and Voltage Charging for Lead-Acid Battery Using Zeta Converter

In areas with unstable PLN electricity supply, the need for an energy storage system becomes very important, especially for charging devices such as mobile phones or laptops. Lead-acid batteries can be a solution, the energy storage process must be carried out with voltage settings that match the characteristics of the battery and do not damage the battery cells. This research develops a zeta converter-based charging system combined with FLC using CC-CV. During the charging process, the output voltage is used to charge the battery by setting a constant current of 3.6 A. This is done continuously until the charging system switches to CV. Testing for 200 minutes showed that charging in CC mode at 3.6 A was achieved for 80 minutes, starting from 50% to 85% SOC. Then, when the converter voltage reached 14.4V, the charging mode switched to CV with constant output voltage, but the current decreased as the battery SOC increased from 85% to 100%, and this process took up to 120 minutes. The system efficiency ranges from 74% to 80% during the CC process and 84% during the CV process. The CC-CV regulation processes are controlled by FLC.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-12-11
DOI
https://doi.org/10.1051/e3sconf/202567401002/pdf
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Adaptive Constant Current and Voltage Charging for Lead-Acid Battery Using Zeta Converter

Springer Link (Chiba Institute of Technology)
Advanced Battery Technologies Research
article

Adaptive Constant Current and Voltage Charging for Lead-Acid Battery Using Zeta Converter

article en

Abstract

In areas with unstable PLN electricity supply, the need for an energy storage system becomes very important, especially for charging devices such as mobile phones or laptops. Lead-acid batteries can be a solution, the energy storage process must be carried out with voltage settings that match the characteristics of the battery and do not damage the battery cells. This research develops a zeta converter-based charging system combined with FLC using CC-CV. During the charging process, the output voltage is used to charge the battery by setting a constant current of 3.6 A. This is done continuously until the charging system switches to CV. Testing for 200 minutes showed that charging in CC mode at 3.6 A was achieved for 80 minutes, starting from 50% to 85% SOC. Then, when the converter voltage reached 14.4V, the charging mode switched to CV with constant output voltage, but the current decreased as the battery SOC increased from 85% to 100%, and this process took up to 120 minutes. The system efficiency ranges from 74% to 80% during the CC process and 84% during the CV process. The CC-CV regulation processes are controlled by FLC.

Springer Link (Chiba Institute of Technology)
Affordable and clean energy
Openalex Percentile: Top 47%
Advanced Battery Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.