Comparative evaluation of three automated urine sediment analyzers excluding cutoff-related trade-offs

Performance comparison of automated urine sediment analyzers is difficult due to cutoff-related trade-offs. In this study, we evaluated and compared UF-5000, UAS800, and Cobas u701 using receiver operating characteristic (ROC) analysis. A total of 774 urine samples were analyzed using manual microscopic examination and microbial culture as the reference test. The area under the ROC curve (ROC-AUC) was compared using DeLong's test. UF-5000, a flow cytometry analyzer, demonstrated significantly better performance than both the automated imaging analyzers UAS800 and Cobas u701 for detecting significant bacteriuria or mucous thread. However, its performance was significantly worse for detecting crystals. UAS800 and Cobas u701 showed generally similar performance, but with significant differences for detecting red blood cells, sperm, and significant bacteriuria. Our results highlight the operating mechanism as a key determinant of performance, and also show that analyzers with similar operating mechanisms can still have significant differences in their performance.

Institutions

Publication Details

Journal
iScience
Published
2025-12-13
DOI
https://doi.org/10.1016/j.isci.2025.114438
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative evaluation of three automated urine sediment analyzers excluding cutoff-related trade-offs

iScience
Biosensors and Analytical Detection
article

Comparative evaluation of three automated urine sediment analyzers excluding cutoff-related trade-offs

article en

Abstract

Performance comparison of automated urine sediment analyzers is difficult due to cutoff-related trade-offs. In this study, we evaluated and compared UF-5000, UAS800, and Cobas u701 using receiver operating characteristic (ROC) analysis. A total of 774 urine samples were analyzed using manual microscopic examination and microbial culture as the reference test. The area under the ROC curve (ROC-AUC) was compared using DeLong's test. UF-5000, a flow cytometry analyzer, demonstrated significantly better performance than both the automated imaging analyzers UAS800 and Cobas u701 for detecting significant bacteriuria or mucous thread. However, its performance was significantly worse for detecting crystals. UAS800 and Cobas u701 showed generally similar performance, but with significant differences for detecting red blood cells, sperm, and significant bacteriuria. Our results highlight the operating mechanism as a key determinant of performance, and also show that analyzers with similar operating mechanisms can still have significant differences in their performance.

iScienceVol. 29(1)
Yonsei University (KR), Severance Hospital (KR)
Openalex Percentile: Top 44%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparative evaluation of three automated urine sediment analyzers excluding cutoff-related trade-offs · iScience (2025) | TGRS Research Map | TGRS