Optimizing landmark selection in head CT: Impact on eye radiation dose and diagnostic quality

Head CT is the most frequent examination in every hospital in Indonesia. Radiation protection on Head CT is important because of the existence of sensitive organ that is eyes.The present study investigated the impact of different cranial baselines on image quality and lens radiation dose in head CT. Diagnostic information was evaluated in six cases, three scanned using the OML and three with the SOML baseline, and subsequently reviewed by three radiologists through a structured questionnaire. Ocular radiation dose was measured in ten additional cases, five per variation, using TLD-100 dosimeters placed on the eyelid. Measured values were compared with the reference provided in ICRP Publication 87 (2000). The findings showed no significant difference in image information between the SOML and OML orientations, as indicated by the T-test result with a p-value of 0.7419. A substantial reduction in radiation dose was observed when using the SOML baseline (6.411-8.747 mGy) compared with the OML baseline (50.729-70.952 mGy). For head CT examinations, it is recommended that the scanogram be aligned parallel to the SOML, as this orientation provides greater protection for the eyes.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-12-11
DOI
https://doi.org/10.1051/bioconf/202520303002/pdf
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing landmark selection in head CT: Impact on eye radiation dose and diagnostic quality

Springer Link (Chiba Institute of Technology)
Radiation Dose and Imaging
article

Optimizing landmark selection in head CT: Impact on eye radiation dose and diagnostic quality

article en

Abstract

Head CT is the most frequent examination in every hospital in Indonesia. Radiation protection on Head CT is important because of the existence of sensitive organ that is eyes.The present study investigated the impact of different cranial baselines on image quality and lens radiation dose in head CT. Diagnostic information was evaluated in six cases, three scanned using the OML and three with the SOML baseline, and subsequently reviewed by three radiologists through a structured questionnaire. Ocular radiation dose was measured in ten additional cases, five per variation, using TLD-100 dosimeters placed on the eyelid. Measured values were compared with the reference provided in ICRP Publication 87 (2000). The findings showed no significant difference in image information between the SOML and OML orientations, as indicated by the T-test result with a p-value of 0.7419. A substantial reduction in radiation dose was observed when using the SOML baseline (6.411-8.747 mGy) compared with the OML baseline (50.729-70.952 mGy). For head CT examinations, it is recommended that the scanogram be aligned parallel to the SOML, as this orientation provides greater protection for the eyes.

Springer Link (Chiba Institute of Technology)
Openalex Percentile: Top 32%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optimizing landmark selection in head CT: Impact on eye radiation dose and diagnostic quality · Springer Link (Chiba Institute of Technology) (2025) | TGRS Research Map | TGRS