Analysis of Structural Parameters’ Influence on Separation Performance in a Gas–Liquid Cyclone Separator

Hydraulic systems are widely used in industry, and gas contamination of hydraulic oil reduces reliability. This study quantifies how the primary geometry of a gas–liquid cyclone separator affects separation performance and proposes an optimal parameter matching scheme. An orthogonal design, combined with numerical simulations and visualization experiments, evaluated five factors: chamber diameter D, chamber height H, overflow pipe diameter Don, insertion depth of the overflow pipe Hon, and underflow orifice diameter Ddown. Considering mixture entrainment, three metrics were used: direct separation efficiency α, split ratio β, and the actual separation efficiency γ, defined as the product of α and β. Range analysis and variance analysis show that β is governed by outlet sizing, with Don contributing 56.87% and Ddown contributing 39.26%. γ is dominated by body scale parameters, with D contributing 58.79%, Hon contributing 21.18%, and H contributing 13.27%. The optimized geometry achieves γ of about 80.8%. Experiments confirm consistent trends from 0.5% to 8% gas volume fraction, with separation generally above 77% and simulation-to-experiment differences below 20% when the gas fraction exceeds 1%.

Institutions

Publication Details

Journal
Processes
Published
2025-12-12
DOI
https://doi.org/10.3390/pr13124021
Citations
1
Primary Topic
Cyclone Separators and Fluid Dynamics
Type
article
Field-Weighted Citation Impact
1.33
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Structural Parameters’ Influence on Separation Performance in a Gas–Liquid Cyclone Separator

1 citations
Processes
Cyclone Separators and Fluid Dynamics
1.33
article

Analysis of Structural Parameters’ Influence on Separation Performance in a Gas–Liquid Cyclone Separator

article en
1 citations

Abstract

Hydraulic systems are widely used in industry, and gas contamination of hydraulic oil reduces reliability. This study quantifies how the primary geometry of a gas–liquid cyclone separator affects separation performance and proposes an optimal parameter matching scheme. An orthogonal design, combined with numerical simulations and visualization experiments, evaluated five factors: chamber diameter D, chamber height H, overflow pipe diameter Don, insertion depth of the overflow pipe Hon, and underflow orifice diameter Ddown. Considering mixture entrainment, three metrics were used: direct separation efficiency α, split ratio β, and the actual separation efficiency γ, defined as the product of α and β. Range analysis and variance analysis show that β is governed by outlet sizing, with Don contributing 56.87% and Ddown contributing 39.26%. γ is dominated by body scale parameters, with D contributing 58.79%, Hon contributing 21.18%, and H contributing 13.27%. The optimized geometry achieves γ of about 80.8%. Experiments confirm consistent trends from 0.5% to 8% gas volume fraction, with separation generally above 77% and simulation-to-experiment differences below 20% when the gas fraction exceeds 1%.

ProcessesVol. 13(12)
Yanshan University (CN), Changchun Institute of Technology (CN), Changchun University (CN)
Industry, innovation and infrastructure
Openalex Percentile: Top 15%
Cyclone Separators and Fluid Dynamics
1.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.