Augmented heat transfer in the solar air heater having hybrid roughness as continuous and discrete V ribs with dimples: a CFD analysis

Poor thermal performance of a solar air heater (SAH) can be improved using artificial roughness on the absorber plate. A few studies have been carried out SAH with the V rib-dimple hybrid structure, generally at micro-scale. In this paper, a numerical investigation has been conducted to examine flow and performance characteristics of a solar air heater (SAH) with novel arrangements of 30° continuous and discrete V ribs with the spherical dimples for Reynolds numbers ( Re ) of 4000-15,000 via ANSYS Fluent. The rib pitch to rib height ratio ( p / e ) of 10.8–18, rib height to hydraulic diameter ratio ( e / D h ) of 0.045–0.075, dimple depth to hydraulic diameter ratio ( d / D h ) of 0.030–0.048 and dimple transverse pitch to longitudinal pitch ratio ( S T / S L ) of 0.59 are considered. The CFD simulation has been validated with an experimental study. The findings reveal that increasing the rib height and dimple depth lead to strong secondary flows in spanwise direction. It also enhances downwash flows with a reduction of the flow recirculation region inside the dimples. The impact of rib height on thermo-hydraulic performance ( THP ) is more apparent than that of dimple depth. The new configuration with p / e = 10.8, e / D h = 0.075 and d / D h = 0.048 significantly augments turbulence kinetic energy, mixing flow and thus heat transfer. The maximum THP of 1.58 is achieved with this configuration at Re = 6000. • Novel configurations with continuous and discrete V ribs with spherical dimples are examined at Re = 4000-15,000. • New hybrid structures are constructed by varying rib height and dimple depth. • The effect of the rib height on Nu is more notable than the dimple depth. • A peak performance of 1.58 is achieved by the original hybrid arrangement with e / D h = 0.075 and d / D h = 0.048 at Re = 6000.

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2025-12-12
DOI
https://doi.org/10.1016/j.csite.2025.107548
Citations
2
Primary Topic
Heat Transfer Mechanisms
Type
article
Field-Weighted Citation Impact
1.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Augmented heat transfer in the solar air heater having hybrid roughness as continuous and discrete V ribs with dimples: a CFD analysis

2 citations
Case Studies in Thermal Engineering
Heat Transfer Mechanisms
1.43
article

Augmented heat transfer in the solar air heater having hybrid roughness as continuous and discrete V ribs with dimples: a CFD analysis

article en
2 citations

Abstract

Poor thermal performance of a solar air heater (SAH) can be improved using artificial roughness on the absorber plate. A few studies have been carried out SAH with the V rib-dimple hybrid structure, generally at micro-scale. In this paper, a numerical investigation has been conducted to examine flow and performance characteristics of a solar air heater (SAH) with novel arrangements of 30° continuous and discrete V ribs with the spherical dimples for Reynolds numbers ( Re ) of 4000-15,000 via ANSYS Fluent. The rib pitch to rib height ratio ( p / e ) of 10.8–18, rib height to hydraulic diameter ratio ( e / D h ) of 0.045–0.075, dimple depth to hydraulic diameter ratio ( d / D h ) of 0.030–0.048 and dimple transverse pitch to longitudinal pitch ratio ( S T / S L ) of 0.59 are considered. The CFD simulation has been validated with an experimental study. The findings reveal that increasing the rib height and dimple depth lead to strong secondary flows in spanwise direction. It also enhances downwash flows with a reduction of the flow recirculation region inside the dimples. The impact of rib height on thermo-hydraulic performance ( THP ) is more apparent than that of dimple depth. The new configuration with p / e = 10.8, e / D h = 0.075 and d / D h = 0.048 significantly augments turbulence kinetic energy, mixing flow and thus heat transfer. The maximum THP of 1.58 is achieved with this configuration at Re = 6000. • Novel configurations with continuous and discrete V ribs with spherical dimples are examined at Re = 4000-15,000. • New hybrid structures are constructed by varying rib height and dimple depth. • The effect of the rib height on Nu is more notable than the dimple depth. • A peak performance of 1.58 is achieved by the original hybrid arrangement with e / D h = 0.075 and d / D h = 0.048 at Re = 6000.

Case Studies in Thermal EngineeringVol. 77
Openalex Percentile: Top 16%
Heat Transfer Mechanisms
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.