Twenty-Four-Hour Central Ambulatory Blood Pressure: Relationship With Measures of Cardiovascular Subclinical Organ Damage in Healthy Individuals.

BACKGROUND: In most, but not all, observational studies, ambulatory central systolic blood pressure (cSBP) is more closely related to left ventricular mass index than ambulatory brachial SBP. However, the association with other markers of subclinical organ damage is poorly understood. We investigated the association between ambulatory brachial SBP or cSBP and measures of subclinical organ damage, together with the influence of waveform calibration method, in a large community-based population of untreated individuals. METHODS: In all, 1311 participants (mean age, 45±18 years; 589 women) had simultaneous measurements of ambulatory brachial and central pressure over 24 hours. Of these, left ventricular mass index was assessed in 675 individuals, carotid intima-media thickness in 610 individuals and carotid-femoral (aortic) pulse-wave velocity in 1091 individuals. RESULTS: Left ventricular mass index was most strongly associated with cSBP, calibrated using mean and diastolic blood pressure, with a β coefficient of 0.237 (95% CI, 0.225-0.453; P<0.001). The adjusted (partial) correlation coefficient for this association was also significantly higher versus both brachial SBP and cSBP derived from calibration using SBP and diastolic blood pressure (P<0.001 for both). The same was true for carotid intima-media thickness (β coefficient=0.141 [95% CI, 0.777-2.502]; P<0.001), although the adjusted correlation coefficients did not differ significantly between ambulatory blood pressure indices. In contrast, aortic pulse-wave velocity shared a similar association with both brachial and central ambulatory pressure, with no obvious effect of waveform calibration method. CONCLUSIONS: Ambulatory cSBP may provide valuable additional information concerning cardiovascular risk, although the method of waveform calibration exerts a marked impact.

Publication Details

Journal
Apollo (University of Cambridge)
Published
2025-12-11
DOI
https://doi.org/10.17863/cam.123885
Primary Topic
Cardiovascular Health and Disease Prevention
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Twenty-Four-Hour Central Ambulatory Blood Pressure: Relationship With Measures of Cardiovascular Subclinical Organ Damage in Healthy Individuals.

Apollo (University of Cambridge)
Cardiovascular Health and Disease Prevention
article

Twenty-Four-Hour Central Ambulatory Blood Pressure: Relationship With Measures of Cardiovascular Subclinical Organ Damage in Healthy Individuals.

article en

Abstract

BACKGROUND: In most, but not all, observational studies, ambulatory central systolic blood pressure (cSBP) is more closely related to left ventricular mass index than ambulatory brachial SBP. However, the association with other markers of subclinical organ damage is poorly understood. We investigated the association between ambulatory brachial SBP or cSBP and measures of subclinical organ damage, together with the influence of waveform calibration method, in a large community-based population of untreated individuals. METHODS: In all, 1311 participants (mean age, 45±18 years; 589 women) had simultaneous measurements of ambulatory brachial and central pressure over 24 hours. Of these, left ventricular mass index was assessed in 675 individuals, carotid intima-media thickness in 610 individuals and carotid-femoral (aortic) pulse-wave velocity in 1091 individuals. RESULTS: Left ventricular mass index was most strongly associated with cSBP, calibrated using mean and diastolic blood pressure, with a β coefficient of 0.237 (95% CI, 0.225-0.453; P<0.001). The adjusted (partial) correlation coefficient for this association was also significantly higher versus both brachial SBP and cSBP derived from calibration using SBP and diastolic blood pressure (P<0.001 for both). The same was true for carotid intima-media thickness (β coefficient=0.141 [95% CI, 0.777-2.502]; P<0.001), although the adjusted correlation coefficients did not differ significantly between ambulatory blood pressure indices. In contrast, aortic pulse-wave velocity shared a similar association with both brachial and central ambulatory pressure, with no obvious effect of waveform calibration method. CONCLUSIONS: Ambulatory cSBP may provide valuable additional information concerning cardiovascular risk, although the method of waveform calibration exerts a marked impact.

Apollo (University of Cambridge)
Good health and well-being
Openalex Percentile: Top 32%
Cardiovascular Health and Disease Prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Twenty-Four-Hour Central Ambulatory Blood Pressure: Relationship With Measures of Cardiovascular Subclinical Organ Damage in Healthy Individuals. · Apollo (University of Cambridge) (2025) | TGRS Research Map | TGRS