Impact of Printing Orientations on the Trueness and Precision of Additively Fabricated Complete Denture Base Before and After Thermal Aging

<b>Objectives:</b> This in vitro study assessed the accuracy (trueness and precision) of different 3D-printed resin denture bases with 0°, 45°, and 90° printing orientations. <b>Methods:</b> Denture base was designed and fabricated using three 3D-printed denture base resins (DentaBASE, Denture 3D+, and FormLabs). Each resin was printed with its own printer and fabricated with different printing orientations, resulting in a total of 72 specimens (n = 8). Trueness and precision were evaluated before and after thermal aging using the superimposition method with best-fit alignment. The data were collected and analyzed using two-way ANOVA followed by post hoc Tukey's test (α = 0.05). <b>Results:</b> The printing orientation significantly affected the trueness of 3D-printed resins (<i>p</i> < 0.001). The highest trueness was observed for NextDent at 0° printing orientation, while the lowest value was observed for ASIGA at 0° and 45° printing orientations. The precision of the denture base was significantly affected by different printing orientations for ASIGA (<i>p</i> = 0.006) and NextDent (<i>p</i> < 0.001) before thermal cycling, while the precision of FormLabs was significantly affected (<i>p</i> = 0.017) after thermal cycling. The highest precision was recorded for FormLabs at 45° printing orientation, while the lowest precision was observed for NextDent at 45° and 90° printing orientations. Moreover, the effect of thermal cycling on trueness was only significant for ASIGA at 0° printing orientation; however, the effect of thermal cycling on precision was significant for NextDent at 0° and 90° printing orientations. A 45° printing orientation provided the most accurate clinical fit. <b>Conclusions:</b> ASIGA showed the lowest trueness, while FormLabs exhibited the lowest precision, revealing performance differences between printers.

Institutions

Publication Details

Journal
Dentistry Journal
Published
2025-12-12
DOI
https://doi.org/10.3390/dj13120598
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Printing Orientations on the Trueness and Precision of Additively Fabricated Complete Denture Base Before and After Thermal Aging

Dentistry Journal
Dental materials and restorations
article

Impact of Printing Orientations on the Trueness and Precision of Additively Fabricated Complete Denture Base Before and After Thermal Aging

article en

Abstract

<b>Objectives:</b> This in vitro study assessed the accuracy (trueness and precision) of different 3D-printed resin denture bases with 0°, 45°, and 90° printing orientations. <b>Methods:</b> Denture base was designed and fabricated using three 3D-printed denture base resins (DentaBASE, Denture 3D+, and FormLabs). Each resin was printed with its own printer and fabricated with different printing orientations, resulting in a total of 72 specimens (n = 8). Trueness and precision were evaluated before and after thermal aging using the superimposition method with best-fit alignment. The data were collected and analyzed using two-way ANOVA followed by post hoc Tukey's test (α = 0.05). <b>Results:</b> The printing orientation significantly affected the trueness of 3D-printed resins (<i>p</i> < 0.001). The highest trueness was observed for NextDent at 0° printing orientation, while the lowest value was observed for ASIGA at 0° and 45° printing orientations. The precision of the denture base was significantly affected by different printing orientations for ASIGA (<i>p</i> = 0.006) and NextDent (<i>p</i> < 0.001) before thermal cycling, while the precision of FormLabs was significantly affected (<i>p</i> = 0.017) after thermal cycling. The highest precision was recorded for FormLabs at 45° printing orientation, while the lowest precision was observed for NextDent at 45° and 90° printing orientations. Moreover, the effect of thermal cycling on trueness was only significant for ASIGA at 0° printing orientation; however, the effect of thermal cycling on precision was significant for NextDent at 0° and 90° printing orientations. A 45° printing orientation provided the most accurate clinical fit. <b>Conclusions:</b> ASIGA showed the lowest trueness, while FormLabs exhibited the lowest precision, revealing performance differences between printers.

Dentistry JournalVol. 13(12)
Ministry of Health (SA), National Guard Health Affairs (SA), Imam Abdulrahman Bin Faisal University (SA)
Openalex Percentile: Top 36%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.