Numerical Simulation of the Combustion Characteristics of a 330 MW Tangentially Fired Boiler with Preheating Combustion Devices Under Various Loads

With the rapid development of renewable energy sources in power generation, utility boilers need to perform load regulation over a wide range to maintain the stability of the power supply system. Preheating combustion technology is a potential approach to achieve wide load range operation, improve combustion stability, and lower NOx emissions from utility boilers. Preheating combustion devices (PCDs) were designed and installed in the reduction zone of a boiler. These devices preheated the coal at an excess air ratio ranging from 0.35 to 0.7 to generate high-temperature gas and char, which effectively reduced NOx formation in the furnace. Numerical studies were conducted to evaluate the combustion performance and nitrogen oxides emissions of a 330 MW utility boiler retrofitted with PCDs at different loads. The simulations were conducted over a load range of 20% to 100% of the rated load, corresponding to an electrical power of 66 MW to 330 MW. The preheated combustion device’s previous experimental data served as the boundary conditions of the preheated product nozzles. The simulation results demonstrated that the retrofitted boiler could operate stably from 20% to 100% of the rated load, maintaining acceptable combustion efficiency and lower NOx emissions. The combustion efficiency gradually dropped with decreasing boiler load, reaching a minimum value of 95.6%. As the load declined, the size of the imaginary tangent circle of the boiler shrank, while the ignition distance increased. Additionally, the variation in NOx concentration with load was complex. The NOx concentration at the furnace outlet was between 102.7 and 220.3 mg/m3, and the preheated products effectively reduced the nitrogen oxides produced by combustion in the furnace at all loads.

Institutions

Publication Details

Journal
Processes
Published
2025-12-12
DOI
https://doi.org/10.3390/pr13124026
Primary Topic
Combustion and flame dynamics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical Simulation of the Combustion Characteristics of a 330 MW Tangentially Fired Boiler with Preheating Combustion Devices Under Various Loads

Processes
Combustion and flame dynamics
article

Numerical Simulation of the Combustion Characteristics of a 330 MW Tangentially Fired Boiler with Preheating Combustion Devices Under Various Loads

article en

Abstract

With the rapid development of renewable energy sources in power generation, utility boilers need to perform load regulation over a wide range to maintain the stability of the power supply system. Preheating combustion technology is a potential approach to achieve wide load range operation, improve combustion stability, and lower NOx emissions from utility boilers. Preheating combustion devices (PCDs) were designed and installed in the reduction zone of a boiler. These devices preheated the coal at an excess air ratio ranging from 0.35 to 0.7 to generate high-temperature gas and char, which effectively reduced NOx formation in the furnace. Numerical studies were conducted to evaluate the combustion performance and nitrogen oxides emissions of a 330 MW utility boiler retrofitted with PCDs at different loads. The simulations were conducted over a load range of 20% to 100% of the rated load, corresponding to an electrical power of 66 MW to 330 MW. The preheated combustion device’s previous experimental data served as the boundary conditions of the preheated product nozzles. The simulation results demonstrated that the retrofitted boiler could operate stably from 20% to 100% of the rated load, maintaining acceptable combustion efficiency and lower NOx emissions. The combustion efficiency gradually dropped with decreasing boiler load, reaching a minimum value of 95.6%. As the load declined, the size of the imaginary tangent circle of the boiler shrank, while the ignition distance increased. Additionally, the variation in NOx concentration with load was complex. The NOx concentration at the furnace outlet was between 102.7 and 220.3 mg/m3, and the preheated products effectively reduced the nitrogen oxides produced by combustion in the furnace at all loads.

ProcessesVol. 13(12)
Northeast Electric Power University (CN)
National Natural Science Foundation of China, People's Government of Jilin Province, Education Department of Jilin Province
Affordable and clean energy
Openalex Percentile: Top 38%
Combustion and flame dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.