Tuning Poly(dimethylsiloxane) Hydrophilization and Coating Stability via the Optimization of Polyethylene Glycol Molecular Weight

Polydimethylsiloxane (PDMS) is widely used in microfluidics and medical devices; however, its inherent hydrophobicity limits its applications. This can be resolved by the formation of polyethylene glycol (PEG)-based hydrophilic coatings. Here, we aimed to prove that PDMS surfaces modified with low molecular weight PEG (400) provided a more stable hydrophilic surface. The lowest contact angle achieved via using PEG400 and the "grafting from" approach was 8.6 ± 3.5°. Under perfusion conditions, imitating arterial and capillary flows, such coatings were considerably stable, and the contact angle was kept at 45.5° after 3 days. Moreover, the applied surface modifications preserved surface roughness, elastic modulus, and optical transparency. Thus, these findings confirmed that the "grafting from" approach with low molecular weight PEG could be the most effective strategy to form hydrophilic PDMS coatings with optimal performance in biomedical applications.

Institutions

Publication Details

Journal
Polymers
Published
2025-12-12
DOI
https://doi.org/10.3390/polym17243296
Primary Topic
Polymer Surface Interaction Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tuning Poly(dimethylsiloxane) Hydrophilization and Coating Stability via the Optimization of Polyethylene Glycol Molecular Weight

Polymers
Polymer Surface Interaction Studies
article

Tuning Poly(dimethylsiloxane) Hydrophilization and Coating Stability via the Optimization of Polyethylene Glycol Molecular Weight

article en

Abstract

Polydimethylsiloxane (PDMS) is widely used in microfluidics and medical devices; however, its inherent hydrophobicity limits its applications. This can be resolved by the formation of polyethylene glycol (PEG)-based hydrophilic coatings. Here, we aimed to prove that PDMS surfaces modified with low molecular weight PEG (400) provided a more stable hydrophilic surface. The lowest contact angle achieved via using PEG400 and the "grafting from" approach was 8.6 ± 3.5°. Under perfusion conditions, imitating arterial and capillary flows, such coatings were considerably stable, and the contact angle was kept at 45.5° after 3 days. Moreover, the applied surface modifications preserved surface roughness, elastic modulus, and optical transparency. Thus, these findings confirmed that the "grafting from" approach with low molecular weight PEG could be the most effective strategy to form hydrophilic PDMS coatings with optimal performance in biomedical applications.

PolymersVol. 17(24)
Sechenov University (RU), Lomonosov Moscow State University (RU), Semenov Institute of Chemical Physics (RU)
Openalex Percentile: Top 42%
Polymer Surface Interaction Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.