Accuracy of Three-Dimensionally Printed, Patient-Specific Drill Guides for Implant Placement in Canine Cervical Vertebrae: A Cadaveric Study

The objective of this study was to assess the accuracy of autoclavable, three-dimensionally (3D) printed drill guides (3DPG) created with a rapid printing protocol and utilized by both an experienced and inexperienced surgeon in constraining the trajectory of drill tracts to intended corridors within canine cervical vertebrae. The 3DPG were designed using computed tomographic (CT) images of six complete cadaveric canine cervical vertebral columns and used to create drill tracts in all vertebrae by both an experienced and a novice surgeon. Repeat CT imaging was used to assess the entry point (EPD) and angular deviation (AD) of the actual versus planned drill tracts. Unintended cortical bone violations were also assessed. A total of 80 3DPG were used to create 144 drill tracts in 42 vertebrae. The overall mean EPD was 1.1 mm (median 0.9 mm, range 0.1-5.1 mm) and the overall mean AD was 7.3° (median 5.2°, range 0.5-33.8°). There were no differences in overall EPD (<i>p</i> = 0.85) or AD (<i>p</i> = 0.20) between the inexperienced and novice surgeons. There were no unintended cortical bone breaches. These 3DPG allowed the creation of safe and accurate drill tracts within the canine cervical spine by both an experienced and an inexperienced surgeon.

Institutions

Publication Details

Journal
Veterinary Sciences
Published
2025-12-12
DOI
https://doi.org/10.3390/vetsci12121190
Primary Topic
Veterinary Orthopedics and Neurology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of Three-Dimensionally Printed, Patient-Specific Drill Guides for Implant Placement in Canine Cervical Vertebrae: A Cadaveric Study

Veterinary Sciences
Veterinary Orthopedics and Neurology
article

Accuracy of Three-Dimensionally Printed, Patient-Specific Drill Guides for Implant Placement in Canine Cervical Vertebrae: A Cadaveric Study

article en

Abstract

The objective of this study was to assess the accuracy of autoclavable, three-dimensionally (3D) printed drill guides (3DPG) created with a rapid printing protocol and utilized by both an experienced and inexperienced surgeon in constraining the trajectory of drill tracts to intended corridors within canine cervical vertebrae. The 3DPG were designed using computed tomographic (CT) images of six complete cadaveric canine cervical vertebral columns and used to create drill tracts in all vertebrae by both an experienced and a novice surgeon. Repeat CT imaging was used to assess the entry point (EPD) and angular deviation (AD) of the actual versus planned drill tracts. Unintended cortical bone violations were also assessed. A total of 80 3DPG were used to create 144 drill tracts in 42 vertebrae. The overall mean EPD was 1.1 mm (median 0.9 mm, range 0.1-5.1 mm) and the overall mean AD was 7.3° (median 5.2°, range 0.5-33.8°). There were no differences in overall EPD (<i>p</i> = 0.85) or AD (<i>p</i> = 0.20) between the inexperienced and novice surgeons. There were no unintended cortical bone breaches. These 3DPG allowed the creation of safe and accurate drill tracts within the canine cervical spine by both an experienced and an inexperienced surgeon.

Veterinary SciencesVol. 12(12)
North Carolina State University (US), Institute of Neuroimmunology of the Slovak Academy of Sciences (SK)
Openalex Percentile: Top 30%
Veterinary Orthopedics and Neurology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.