Celovita ocena zmogljivosti zobniških prenosov vetrnih turbin z drsnimi ležaji

This paper presents a thermodynamic analysis of two types of heat pumps integrated into the heating, ventilation, and air conditioning (HVAC) system of the “Bajina Bašta” hydropower plant located in Serbia. The study aims to replace existing electric boilers with more energy-efficient solutions by utilising renewable heat sources. A comparative evaluation of water source heat pump (WSHP) and air source heat pump (ASHP) configurations was conducted using a custom-developed MATLAB model based on CoolProp data of working fluids. The analysis was supported by real data obtained through in situ measurements of air and water temperatures at the selected location, ensuring accurate input parameters for the simulations. Five refrigerants (R-410A, R-407C, R-134a, R-32, and R-1270) were used, and R-32 was selected as the optimal working fluid because of its high efficiency, moderate flammability, and low environmental impact. The lowest coefficient of performance (COP) for the WSHP was 3.27 in January, while the seasonal coefficient of performance (SCOP) reached 3.36, approximately 15.5 % higher than the ASHP counterpart (SCOP = 2.91). The study confirms that, upon analyzing the entire heating period, WSHP systems are technically and environmentally superior to ASHPs in the locations studied. The proposed configuration, based on real measured data and obtained results, can significantly improve energy efficiency and reduce internal electricity consumption in hydropower plants, thereby supporting the decarbonisation of large-scale renewable energy facilities. While most previous studies have focused on improving energy efficiency in buildings, this work demonstrates the substantial yet underexplored potential for efficiency improvements in the electricity production sector in Serbia. The study specifically examines hydropower plants in Serbia, where heating and air conditioning systems built in the 1960s remain highly energy inefficient. By quantifying the benefits of integrating WSHP and ASHP systems, the research highlights a pathway toward significantly enhancing the energy efficiency of hydropower infrastructures.

Publication Details

Journal
Repository of the University of Ljubljana (University of Ljubljana)
Published
2025-10-23
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Celovita ocena zmogljivosti zobniških prenosov vetrnih turbin z drsnimi ležaji

Repository of the University of Ljubljana (University of Ljubljana)
Geothermal Energy Systems and Applications
article

Celovita ocena zmogljivosti zobniških prenosov vetrnih turbin z drsnimi ležaji

article en

Abstract

This paper presents a thermodynamic analysis of two types of heat pumps integrated into the heating, ventilation, and air conditioning (HVAC) system of the “Bajina Bašta” hydropower plant located in Serbia. The study aims to replace existing electric boilers with more energy-efficient solutions by utilising renewable heat sources. A comparative evaluation of water source heat pump (WSHP) and air source heat pump (ASHP) configurations was conducted using a custom-developed MATLAB model based on CoolProp data of working fluids. The analysis was supported by real data obtained through in situ measurements of air and water temperatures at the selected location, ensuring accurate input parameters for the simulations. Five refrigerants (R-410A, R-407C, R-134a, R-32, and R-1270) were used, and R-32 was selected as the optimal working fluid because of its high efficiency, moderate flammability, and low environmental impact. The lowest coefficient of performance (COP) for the WSHP was 3.27 in January, while the seasonal coefficient of performance (SCOP) reached 3.36, approximately 15.5 % higher than the ASHP counterpart (SCOP = 2.91). The study confirms that, upon analyzing the entire heating period, WSHP systems are technically and environmentally superior to ASHPs in the locations studied. The proposed configuration, based on real measured data and obtained results, can significantly improve energy efficiency and reduce internal electricity consumption in hydropower plants, thereby supporting the decarbonisation of large-scale renewable energy facilities. While most previous studies have focused on improving energy efficiency in buildings, this work demonstrates the substantial yet underexplored potential for efficiency improvements in the electricity production sector in Serbia. The study specifically examines hydropower plants in Serbia, where heating and air conditioning systems built in the 1960s remain highly energy inefficient. By quantifying the benefits of integrating WSHP and ASHP systems, the research highlights a pathway toward significantly enhancing the energy efficiency of hydropower infrastructures.

Repository of the University of Ljubljana (University of Ljubljana)
Affordable and clean energy
Openalex Percentile: Top 55%
Geothermal Energy Systems and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Celovita ocena zmogljivosti zobniških prenosov vetrnih turbin z drsnimi ležaji · Repository of the University of Ljubljana (University of Ljubljana) (2025) | TGRS Research Map | TGRS