Sensitive and Selective Chromatographic Method to Determine Vanadium in Commercial Phosphoric Acid

The spectrophotometric method adopting N-Benzoyl-N-phenylhydroxylamine was exechted for ascertaining vanadium in environmental samples. high performance liquid chromatography (HPLC) system equipped with a C18 RP column was used to determine vanadium in wet phosphoric acid and phosphate samples. A rapid pre-column response of vanadium with 5-Br-PADAP was used without prior separation or adding any masking agents. The results showed that, the chelates were detected after being injected through the column by UV- Vis detector at wavelength 585 nm. The molar absorptivity is 5.5 x104 and the retention time is 6.3 minutes. The sensitivity of this reagent is equal to twice as high as the use of (PAR) reagent. The RSD was 1.7% for weak concentrations to 0.22% for high concentrations and the relative error (RE) was between 3.21% and 1.07%. In conclusion the method of the currently study was found highly sensitive and selective and the results show a good accuracy and precision.

Institutions

Publication Details

Journal
Biology Medicine & Natural Product Chemistry
Published
2025-10-01
DOI
https://doi.org/10.14421/biomedich.2025.142.725-729
Primary Topic
Vanadium and Halogenation Chemistry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sensitive and Selective Chromatographic Method to Determine Vanadium in Commercial Phosphoric Acid

Biology Medicine & Natural Product Chemistry
Vanadium and Halogenation Chemistry
article

Sensitive and Selective Chromatographic Method to Determine Vanadium in Commercial Phosphoric Acid

article en

Abstract

The spectrophotometric method adopting N-Benzoyl-N-phenylhydroxylamine was exechted for ascertaining vanadium in environmental samples. high performance liquid chromatography (HPLC) system equipped with a C18 RP column was used to determine vanadium in wet phosphoric acid and phosphate samples. A rapid pre-column response of vanadium with 5-Br-PADAP was used without prior separation or adding any masking agents. The results showed that, the chelates were detected after being injected through the column by UV- Vis detector at wavelength 585 nm. The molar absorptivity is 5.5 x104 and the retention time is 6.3 minutes. The sensitivity of this reagent is equal to twice as high as the use of (PAR) reagent. The RSD was 1.7% for weak concentrations to 0.22% for high concentrations and the relative error (RE) was between 3.21% and 1.07%. In conclusion the method of the currently study was found highly sensitive and selective and the results show a good accuracy and precision.

Biology Medicine & Natural Product ChemistryVol. 14(2)
Hadhramout University (YE)
Clean water and sanitation
Openalex Percentile: Top 46%
Vanadium and Halogenation Chemistry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Sensitive and Selective Chromatographic Method to Determine Vanadium in Commercial Phosphoric Acid · Biology Medicine & Natural Product Chemistry (2025) | TGRS Research Map | TGRS