Preliminary hemolysis evaluation of MR-conditional blood pumps

Purpose: Magnetic resonance imaging (MRI) during cardiopulmonary bypass is hindered by the incompatibility of conventional heart-lung machines, which contain metallic components that interfere with the MRI environment. This study evaluates the hemolytic performance of three MR-conditional blood pump prototypes-roller, non-occlusive roller, and centrifugal-designed for use during neonatal surgery. Materials and methods: Each pump was tested using acid-citrate dextrose-stabilized bovine blood at a neonatal-relevant flow rate of 1 L/min. Due to limitations of the setup, a low pressure head of 10 mmHg was applied uniformly across experiments. Hemolysis was assessed using normalized index of hemolysis, and a linear mixed-effects model was applied to account for experimental variability. Results: The roller pump showed the lowest hemolysis (1.84 ± 1.90 mg/100 L). The centrifugal pump showed the highest (8.43 ± 1.63 mg/100 L), alongside mechanical leakage. Random effects (SD = 2.07) indicated moderate inter-experimental variability. Conclusion: While all prototypes performed comparably to standard references under controlled conditions, further testing at physiological pressure levels and stricter adherence to ASTM F1841 is necessary for broader validation.

Publication Details

Journal
Universität Zürich, ZORA
Published
2025-10-23
DOI
https://doi.org/10.5167/uzh-281180
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preliminary hemolysis evaluation of MR-conditional blood pumps

Universität Zürich, ZORA
Mechanical Circulatory Support Devices
article

Preliminary hemolysis evaluation of MR-conditional blood pumps

article en

Abstract

Purpose: Magnetic resonance imaging (MRI) during cardiopulmonary bypass is hindered by the incompatibility of conventional heart-lung machines, which contain metallic components that interfere with the MRI environment. This study evaluates the hemolytic performance of three MR-conditional blood pump prototypes-roller, non-occlusive roller, and centrifugal-designed for use during neonatal surgery. Materials and methods: Each pump was tested using acid-citrate dextrose-stabilized bovine blood at a neonatal-relevant flow rate of 1 L/min. Due to limitations of the setup, a low pressure head of 10 mmHg was applied uniformly across experiments. Hemolysis was assessed using normalized index of hemolysis, and a linear mixed-effects model was applied to account for experimental variability. Results: The roller pump showed the lowest hemolysis (1.84 ± 1.90 mg/100 L). The centrifugal pump showed the highest (8.43 ± 1.63 mg/100 L), alongside mechanical leakage. Random effects (SD = 2.07) indicated moderate inter-experimental variability. Conclusion: While all prototypes performed comparably to standard references under controlled conditions, further testing at physiological pressure levels and stricter adherence to ASTM F1841 is necessary for broader validation.

Universität Zürich, ZORA
Good health and well-being
Openalex Percentile: Top 44%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Preliminary hemolysis evaluation of MR-conditional blood pumps · Universität Zürich, ZORA (2025) | TGRS Research Map | TGRS