Airflow, CO2 Inhalation, and Firmness Characteristics of Commercial Infant Products

ABSTRACT This study introduces three different test methods to evaluate suffocation-related hazards in infant products that result from three specific hazards: mechanical occlusion of the nares, resistance to airflow, and abnormal gas exchange, particularly carbon dioxide (CO2) inhalation. A range of infant products and reference materials (crib mattresses, lounger pillows, mesh and traditional crib bumpers, inclined sleepers, blankets, and lambs wool) were tested using firmness testing (product deformation under 10 Newton load) to assess nasal occlusion risks, airflow testing (at 0° and 15° head rotation of a 3-inch hemispheric probe with nares) to evaluate resistance to breathing, and CO2 inhalation testing (with the same probe as airflow testing) to identify potential suffocation hazards not addressed by existing standards. Firm and flat surfaces like crib mattresses were shown to reduce suffocation hazards because light head rotations improved airflow and decreased CO2 retention. Conversely, soft, concave, or polyfilled products (lounger pillows, inclined sleepers, traditional crib bumpers) exhibited all three suffocation-related risks, with minimal improvement even with head rotation. Lambs wool, despite allowing airflow, had high CO2 retention levels, representing a significant risk for hypercapnia or hypoxia. Mesh crib bumpers demonstrated low airflow resistance and safe CO2 levels. Firmness, airflow resistance, and CO2 retention testing revealed distinct suffocation hazards in various infant products. Firm, flat surfaces mitigate risk, whereas soft or concave products increase suffocation-related dangers. This research highlights the need for comprehensive safety evaluations of infant products during the design process, particularly focusing on firmness, airflow, and gas exchange, to prevent suffocation risks in infant sleep environments.

Institutions

Publication Details

Journal
Journal of Testing and Evaluation
Published
2025-08-04
DOI
https://doi.org/10.1520/jte20250030
Primary Topic
Neonatal skin health care
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Airflow, CO2 Inhalation, and Firmness Characteristics of Commercial Infant Products

Journal of Testing and Evaluation
Neonatal skin health care
article

Airflow, CO2 Inhalation, and Firmness Characteristics of Commercial Infant Products

article en

Abstract

ABSTRACT This study introduces three different test methods to evaluate suffocation-related hazards in infant products that result from three specific hazards: mechanical occlusion of the nares, resistance to airflow, and abnormal gas exchange, particularly carbon dioxide (CO2) inhalation. A range of infant products and reference materials (crib mattresses, lounger pillows, mesh and traditional crib bumpers, inclined sleepers, blankets, and lambs wool) were tested using firmness testing (product deformation under 10 Newton load) to assess nasal occlusion risks, airflow testing (at 0° and 15° head rotation of a 3-inch hemispheric probe with nares) to evaluate resistance to breathing, and CO2 inhalation testing (with the same probe as airflow testing) to identify potential suffocation hazards not addressed by existing standards. Firm and flat surfaces like crib mattresses were shown to reduce suffocation hazards because light head rotations improved airflow and decreased CO2 retention. Conversely, soft, concave, or polyfilled products (lounger pillows, inclined sleepers, traditional crib bumpers) exhibited all three suffocation-related risks, with minimal improvement even with head rotation. Lambs wool, despite allowing airflow, had high CO2 retention levels, representing a significant risk for hypercapnia or hypoxia. Mesh crib bumpers demonstrated low airflow resistance and safe CO2 levels. Firmness, airflow resistance, and CO2 retention testing revealed distinct suffocation hazards in various infant products. Firm, flat surfaces mitigate risk, whereas soft or concave products increase suffocation-related dangers. This research highlights the need for comprehensive safety evaluations of infant products during the design process, particularly focusing on firmness, airflow, and gas exchange, to prevent suffocation risks in infant sleep environments.

Journal of Testing and EvaluationVol. 53(6)
Boise State University (US), MDS Associates (United States) (US), University of Arkansas for Medical Sciences (US), The University of Texas at Austin (US)
Openalex Percentile: Top 27%
Neonatal skin health care
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Airflow, CO2 Inhalation, and Firmness Characteristics of Commercial Infant Products · Journal of Testing and Evaluation (2025) | TGRS Research Map | TGRS