High-performance electrochemical sensing of tetracycline via functionalised reduced graphene oxide nanocomposites

• rGO-ES-Pd nanocomposite-based sensor developed for tetracycline detection. • Sensor shows high sensitivity (LOD: 1.51 × 10 −7 M) and broad linear range (0.01–5.0 μM). • Emeraldine salt and palladium nanoparticles enhance electron transfer and matrix selectivity. • The method exhibits low interference from ibuprofen, erythromycin, and amoxicillin. • Sensor validated in urine, river water, and wastewater with high reproducibility. The detection of antibiotic residues, particularly tetracyclines (TC), is crucial due to their potential risks to public health and environmental safety. This study reports the development of a selective and sensitive electrochemical sensor based on reduced graphene oxide functionalized with emeraldine salt and palladium nanoparticles (rGO-ES-Pd) for the detection of TC in simulated samples, urine, surface water, and wastewater. The rGO-ES-Pd nanocomposite was synthesised via a wet chemical method and drop-cast onto a glassy carbon electrode (GCE) to fabricate the rGO-ES-Pd/GCE sensor. To evaluate the impact of different polyaniline oxidation states, three additional nanocomposites, rGO-EB-Pd (emeraldine base), rGO-PG-Pd (pernigraniline), and rGO-LE-Pd (leucoemeraldine), were also prepared and tested. Comprehensive characterisation was performed using transmission electron microscopy (TEM), Fourier-transform infrared spectroscopy (FTIR), powder X-ray diffraction (XRD), electrochemical impedance spectroscopy (EIS), and cyclic voltammetry (CV). Among the tested nanocomposites, the rGO-ES-Pd/GCE sensor exhibited the highest electrocatalytic activity for TC detection, with a pH-dependent peak current response in the potential range of 0.1–0.4 V. The sensor demonstrated a wide linear detection range (0.01–5.0 × 10 −6 M) and a low detection limit (1.51 × 10 −7 M). Selectivity studies in the presence of common interfering substances, ibuprofen, erythromycin, and amoxicillin, revealed minimal interference and a low relative standard deviation (RSD) of 3.29 %, confirming the robustness of the sensor. The developed electrochemical method was successfully applied to detect TC in real environmental (river water, wastewater influent) and biological (urine) samples, showing excellent reproducibility and long-term stability.

Publication Details

Journal
Energy Nexus
Published
2025-12-11
DOI
https://doi.org/10.1016/j.nexus.2025.100619
Citations
1
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-performance electrochemical sensing of tetracycline via functionalised reduced graphene oxide nanocomposites

1 citations
Energy Nexus
Electrochemical sensors and biosensors
0.73
article

High-performance electrochemical sensing of tetracycline via functionalised reduced graphene oxide nanocomposites

article en
1 citations

Abstract

• rGO-ES-Pd nanocomposite-based sensor developed for tetracycline detection. • Sensor shows high sensitivity (LOD: 1.51 × 10 −7 M) and broad linear range (0.01–5.0 μM). • Emeraldine salt and palladium nanoparticles enhance electron transfer and matrix selectivity. • The method exhibits low interference from ibuprofen, erythromycin, and amoxicillin. • Sensor validated in urine, river water, and wastewater with high reproducibility. The detection of antibiotic residues, particularly tetracyclines (TC), is crucial due to their potential risks to public health and environmental safety. This study reports the development of a selective and sensitive electrochemical sensor based on reduced graphene oxide functionalized with emeraldine salt and palladium nanoparticles (rGO-ES-Pd) for the detection of TC in simulated samples, urine, surface water, and wastewater. The rGO-ES-Pd nanocomposite was synthesised via a wet chemical method and drop-cast onto a glassy carbon electrode (GCE) to fabricate the rGO-ES-Pd/GCE sensor. To evaluate the impact of different polyaniline oxidation states, three additional nanocomposites, rGO-EB-Pd (emeraldine base), rGO-PG-Pd (pernigraniline), and rGO-LE-Pd (leucoemeraldine), were also prepared and tested. Comprehensive characterisation was performed using transmission electron microscopy (TEM), Fourier-transform infrared spectroscopy (FTIR), powder X-ray diffraction (XRD), electrochemical impedance spectroscopy (EIS), and cyclic voltammetry (CV). Among the tested nanocomposites, the rGO-ES-Pd/GCE sensor exhibited the highest electrocatalytic activity for TC detection, with a pH-dependent peak current response in the potential range of 0.1–0.4 V. The sensor demonstrated a wide linear detection range (0.01–5.0 × 10 −6 M) and a low detection limit (1.51 × 10 −7 M). Selectivity studies in the presence of common interfering substances, ibuprofen, erythromycin, and amoxicillin, revealed minimal interference and a low relative standard deviation (RSD) of 3.29 %, confirming the robustness of the sensor. The developed electrochemical method was successfully applied to detect TC in real environmental (river water, wastewater influent) and biological (urine) samples, showing excellent reproducibility and long-term stability.

Energy NexusVol. 21
Clean water and sanitation
Openalex Percentile: Top 20%
Electrochemical sensors and biosensors
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.