Reducing patient to patient airborne exposure in patient and isolation rooms with two patients

Airborne transmission in hospital patient rooms may take place both in patient healthcare worker (HCW) interaction, but also between patients sharing the same room. A protective flow concept with dynamic airflow control, individual thermal environment and protective task airflow pattern has been developed and its efficiency in reducing HCW exposure risk as well as the thermal acceptance been verified in the previous stages of research for both patient and isolation rooms. In the recent study the concept performance has been studied in a room with two patient beds both with individual protective flow arrangement. The research question was, whether the protective flow concept provided enhanced protection on patient to patient exposure compared to traditional mixing ventilation. The research was conducted for both normal patient room and isolation room situations. The protective ventilation was able to keep the normalized concentration below 0.72 near exposed patient’s head in all four test conditions. It prevented the tracer gas to spread evenly to the patient room. The best protection, concentration clearly below 0.5 for the exposed patient was reached with the elevated airflow rate and having the curtain between patient beds.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-12-05
DOI
https://doi.org/10.1051/e3sconf/202567201008/pdf
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reducing patient to patient airborne exposure in patient and isolation rooms with two patients

Springer Link (Chiba Institute of Technology)
Infection Control and Ventilation
article

Reducing patient to patient airborne exposure in patient and isolation rooms with two patients

article en

Abstract

Airborne transmission in hospital patient rooms may take place both in patient healthcare worker (HCW) interaction, but also between patients sharing the same room. A protective flow concept with dynamic airflow control, individual thermal environment and protective task airflow pattern has been developed and its efficiency in reducing HCW exposure risk as well as the thermal acceptance been verified in the previous stages of research for both patient and isolation rooms. In the recent study the concept performance has been studied in a room with two patient beds both with individual protective flow arrangement. The research question was, whether the protective flow concept provided enhanced protection on patient to patient exposure compared to traditional mixing ventilation. The research was conducted for both normal patient room and isolation room situations. The protective ventilation was able to keep the normalized concentration below 0.72 near exposed patient’s head in all four test conditions. It prevented the tracer gas to spread evenly to the patient room. The best protection, concentration clearly below 0.5 for the exposed patient was reached with the elevated airflow rate and having the curtain between patient beds.

Springer Link (Chiba Institute of Technology)
Openalex Percentile: Top 30%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Reducing patient to patient airborne exposure in patient and isolation rooms with two patients · Springer Link (Chiba Institute of Technology) (2025) | TGRS Research Map | TGRS