Towards a maximum wind speed for ventilated asbestos removal worksites

To prevent public and occupational exposure to hazardous airborne fibres during asbestos abatement, regulations impose to maintain worksites at a negative pressure compared to outside, and to dilute indoor fibre concentration by means of a minimum air change rate. However, recent studies have revealed significant effects of wind on the containment of asbestos worksites. The wind can induce negative external pressures with a magnitude higher than the internal pressure produced by mechanical ventilation, thus breaching the containment. This research study proposes to determine a wind speed threshold above which it becomes practically impossible to ensure the worksite containment. The approach followed is based on transient simulations of ventilation networks, using the SYLVIA tool, supplemented by wind pressures from the Tokyo Polytechnic University database. A total of 360 combinations of wind conditions and worksite configurations were evaluated. The results highlight two wind speed thresholds (defined at 10 m height) for design pressures from -10 to -40 Pa: (1) below 6.5 m/s, no significant containment breach is identified, and (2) above 12.5 m/s, the robustness of all containments is questioned regardless the wind direction. These findings can be used by preventers and specialized companies during asbestos abatement or other worksites under containment.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-12-05
DOI
https://doi.org/10.1051/e3sconf/202567205004/pdf
Primary Topic
Occupational and environmental lung diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Towards a maximum wind speed for ventilated asbestos removal worksites

Springer Link (Chiba Institute of Technology)
Occupational and environmental lung diseases
article

Towards a maximum wind speed for ventilated asbestos removal worksites

article en

Abstract

To prevent public and occupational exposure to hazardous airborne fibres during asbestos abatement, regulations impose to maintain worksites at a negative pressure compared to outside, and to dilute indoor fibre concentration by means of a minimum air change rate. However, recent studies have revealed significant effects of wind on the containment of asbestos worksites. The wind can induce negative external pressures with a magnitude higher than the internal pressure produced by mechanical ventilation, thus breaching the containment. This research study proposes to determine a wind speed threshold above which it becomes practically impossible to ensure the worksite containment. The approach followed is based on transient simulations of ventilation networks, using the SYLVIA tool, supplemented by wind pressures from the Tokyo Polytechnic University database. A total of 360 combinations of wind conditions and worksite configurations were evaluated. The results highlight two wind speed thresholds (defined at 10 m height) for design pressures from -10 to -40 Pa: (1) below 6.5 m/s, no significant containment breach is identified, and (2) above 12.5 m/s, the robustness of all containments is questioned regardless the wind direction. These findings can be used by preventers and specialized companies during asbestos abatement or other worksites under containment.

Springer Link (Chiba Institute of Technology)
Affordable and clean energy
Openalex Percentile: Top 30%
Occupational and environmental lung diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.