Testing and comparing of portable air cleaners for indoor aerosol particle removal in laboratory environments

This study aims to test the performance of eight commercial portable air cleaner devices (ACDs) (i.e., ACD1-ACD8) in a standard test chamber (STC) to remove aerosols. The test has been performed according to ANSI/AHAM standard AC-1-2020, and also focus on the variation at particle size. In addition, it compares differences in clean air delivery rates (CADR) of three ACDs tested in the STC with results obtained from measurements in a large test chamber (LTC). Both tests were conducted in a controlled STC and LTC with a volume of 28.4 m3 and 202.0 m3, respectively. Multiple modes of each ACD were evaluated, with tests repeated three times for each mode. The results show the difference in performance of ACDs in terms of CADR, due to the specific technology used by ACD and the specifications of the system. Some devices were less able to remove the aerosols that were used as contaminant in this research. The results also show that there is an effect of the room size on the CADR performance, with larger effects at lower CADR values. Therefore, theoretical values from the standard should not be assumed as CADR values for performance in practice. The results of this paper are intended to support future experimental studies of aerosol removal using portable ACDs in more realistic situation, such as classrooms, to enable a comparison between theoretical and actual CADR values in practice.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-12-05
DOI
https://doi.org/10.1051/e3sconf/202567207015/pdf
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Testing and comparing of portable air cleaners for indoor aerosol particle removal in laboratory environments

Springer Link (Chiba Institute of Technology)
Indoor Air Quality and Microbial Exposure
article

Testing and comparing of portable air cleaners for indoor aerosol particle removal in laboratory environments

article en

Abstract

This study aims to test the performance of eight commercial portable air cleaner devices (ACDs) (i.e., ACD1-ACD8) in a standard test chamber (STC) to remove aerosols. The test has been performed according to ANSI/AHAM standard AC-1-2020, and also focus on the variation at particle size. In addition, it compares differences in clean air delivery rates (CADR) of three ACDs tested in the STC with results obtained from measurements in a large test chamber (LTC). Both tests were conducted in a controlled STC and LTC with a volume of 28.4 m3 and 202.0 m3, respectively. Multiple modes of each ACD were evaluated, with tests repeated three times for each mode. The results show the difference in performance of ACDs in terms of CADR, due to the specific technology used by ACD and the specifications of the system. Some devices were less able to remove the aerosols that were used as contaminant in this research. The results also show that there is an effect of the room size on the CADR performance, with larger effects at lower CADR values. Therefore, theoretical values from the standard should not be assumed as CADR values for performance in practice. The results of this paper are intended to support future experimental studies of aerosol removal using portable ACDs in more realistic situation, such as classrooms, to enable a comparison between theoretical and actual CADR values in practice.

Springer Link (Chiba Institute of Technology)
Industry, innovation and infrastructure
Openalex Percentile: Top 35%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.