Investigation on airflow distribution for operating rooms through numerical simulation and field measurement

Operating rooms in hospitals are vital for maintaining controlled indoor conditions and preventing infections. This study assesses the pressurization, temperature, humidity, air exchange, and particle levels in a local hospital’s operating rooms. By combining on-site measurements and computer simulations, the research provides a comprehensive analysis, including an examination of HVAC system improvement. Results reveal that the updated HVAC system markedly enhances pressurization management, notably reducing infection risks, especially during door opening. Computational fluid dynamics simulations also identify airflow disruptions from equipment, proposing improvements like adjusting the return air height and optimizing the air curtain with various incident angles around the High-Efficiency Particulate Air (HEPA) filter above the operating table. Findings emphasize the importance of maintaining a 40 cm high return air grille to minimize contamination stagnation and a 45° inclined air curtain to enhance contamination control effectiveness throughout the operating rooms.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-12-05
DOI
https://doi.org/10.1051/e3sconf/202567207001/pdf
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation on airflow distribution for operating rooms through numerical simulation and field measurement

Springer Link (Chiba Institute of Technology)
Infection Control and Ventilation
article

Investigation on airflow distribution for operating rooms through numerical simulation and field measurement

article en

Abstract

Operating rooms in hospitals are vital for maintaining controlled indoor conditions and preventing infections. This study assesses the pressurization, temperature, humidity, air exchange, and particle levels in a local hospital’s operating rooms. By combining on-site measurements and computer simulations, the research provides a comprehensive analysis, including an examination of HVAC system improvement. Results reveal that the updated HVAC system markedly enhances pressurization management, notably reducing infection risks, especially during door opening. Computational fluid dynamics simulations also identify airflow disruptions from equipment, proposing improvements like adjusting the return air height and optimizing the air curtain with various incident angles around the High-Efficiency Particulate Air (HEPA) filter above the operating table. Findings emphasize the importance of maintaining a 40 cm high return air grille to minimize contamination stagnation and a 45° inclined air curtain to enhance contamination control effectiveness throughout the operating rooms.

Springer Link (Chiba Institute of Technology)
Good health and well-being
Openalex Percentile: Top 30%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Investigation on airflow distribution for operating rooms through numerical simulation and field measurement · Springer Link (Chiba Institute of Technology) (2025) | TGRS Research Map | TGRS