Evaluation of ventilation performance and occupants’ ventilation practice in a renovated multi-floor apartment building with hybrid ventilation: A case study

This study presents a case study that evaluates the performance of ventilation system in two renovated 12-floor residential buildings in Norway. New room ventilation units (RVUs) with heat recovery are installed in each apartment. The results from questionnaire survey reveal that 42% of respondents never use the RVUs, while 44% operate them daily. Dynamic simulations in IDA ICE are performed with different ventilation scenario to evaluate the air quality in master bedrooms. The results show that both RVUs operation and window opening can provide satisfactory air quality; without these ventilation methods, high CO2 concentrations are observed, with the average CO2 concentrations exceeding recommended threshold of 1000 ppm in most months. It is recommended to implement a more effective control strategy in the new ventilation system.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-12-05
DOI
https://doi.org/10.1051/e3sconf/202567202024/pdf
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of ventilation performance and occupants’ ventilation practice in a renovated multi-floor apartment building with hybrid ventilation: A case study

Springer Link (Chiba Institute of Technology)
Building Energy and Comfort Optimization
article

Evaluation of ventilation performance and occupants’ ventilation practice in a renovated multi-floor apartment building with hybrid ventilation: A case study

article en

Abstract

This study presents a case study that evaluates the performance of ventilation system in two renovated 12-floor residential buildings in Norway. New room ventilation units (RVUs) with heat recovery are installed in each apartment. The results from questionnaire survey reveal that 42% of respondents never use the RVUs, while 44% operate them daily. Dynamic simulations in IDA ICE are performed with different ventilation scenario to evaluate the air quality in master bedrooms. The results show that both RVUs operation and window opening can provide satisfactory air quality; without these ventilation methods, high CO2 concentrations are observed, with the average CO2 concentrations exceeding recommended threshold of 1000 ppm in most months. It is recommended to implement a more effective control strategy in the new ventilation system.

Springer Link (Chiba Institute of Technology)
Sustainable cities and communities
Openalex Percentile: Top 43%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of ventilation performance and occupants’ ventilation practice in a renovated multi-floor apartment building with hybrid ventilation: A case study · Springer Link (Chiba Institute of Technology) (2025) | TGRS Research Map | TGRS