Calculation tool for co-evaluating of ventilation energy performance and indoor air quality

Building energy consumption constitutes one third of the global energy use and one quarter of carbon dioxide emissions. Heating, ventilation and air conditioning HVAC systems consume 38% of the total building energy consumption. HVAC systems are tasked to provide clean air into the indoor space to maintain indoor air quality (IAQ) and thermal comfort. Therefore, balancing between HVAC energy consumption and optimal IAQ is one of the crucial questions when aiming to reduce building energy consumption. This paper presents a calculation tool for co-evaluation of ventilation energy performance and IAQ. The tool is then exploited to study a theoretical office space using four different ventilation control strategies. The results show that while all the simulated control strategies could maintain similar levels of IAQ, significant differences were demonstrated in their energy performance. The results show that adjusting ventilation rate to match occupancy and implementing efficient heat recovery unit demonstrated significant energy savings potential.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-12-05
DOI
https://doi.org/10.1051/e3sconf/202567201038/pdf
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calculation tool for co-evaluating of ventilation energy performance and indoor air quality

Springer Link (Chiba Institute of Technology)
Building Energy and Comfort Optimization
article

Calculation tool for co-evaluating of ventilation energy performance and indoor air quality

article en

Abstract

Building energy consumption constitutes one third of the global energy use and one quarter of carbon dioxide emissions. Heating, ventilation and air conditioning HVAC systems consume 38% of the total building energy consumption. HVAC systems are tasked to provide clean air into the indoor space to maintain indoor air quality (IAQ) and thermal comfort. Therefore, balancing between HVAC energy consumption and optimal IAQ is one of the crucial questions when aiming to reduce building energy consumption. This paper presents a calculation tool for co-evaluation of ventilation energy performance and IAQ. The tool is then exploited to study a theoretical office space using four different ventilation control strategies. The results show that while all the simulated control strategies could maintain similar levels of IAQ, significant differences were demonstrated in their energy performance. The results show that adjusting ventilation rate to match occupancy and implementing efficient heat recovery unit demonstrated significant energy savings potential.

Springer Link (Chiba Institute of Technology)
Affordable and clean energy
Openalex Percentile: Top 43%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.