User comfort in a laboratory assessed though CFD simulation

Ventilation in industrial laboratories must guarantee the safety of operators as well as their aeraulic and thermal comfort to allow the prolonged use of equipment. The laboratory presented here contains several fume hoods with their own suction system, as well as a centralized ventilation system running through the entire room. The extraction is thus done at the level of the fume hoods as well as by a sheath. Blowing also takes place via a duct passing through each room. This laboratory being under construction, CFD numerical simulations were used here to help define the ventilation system to be implemented as well as to assess the comfort of the users of the room. The nature of the blowing duct (perforated duct or duct equipped with diffusers) was thus chosen according to the comfort criteria defined by the Fanger model or DR model (for Draft Rate). This model is based on a semi-empirical formulation to determine the percentage of people bothered by the airflow in a room. The performance of the ventilation system was also estimated according to the occupation of the premises and the activity in progress, in particular the opening or closing of the fume hoods.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-12-05
DOI
https://doi.org/10.1051/e3sconf/202567207028/pdf
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

User comfort in a laboratory assessed though CFD simulation

Springer Link (Chiba Institute of Technology)
Infection Control and Ventilation
article

User comfort in a laboratory assessed though CFD simulation

article en

Abstract

Ventilation in industrial laboratories must guarantee the safety of operators as well as their aeraulic and thermal comfort to allow the prolonged use of equipment. The laboratory presented here contains several fume hoods with their own suction system, as well as a centralized ventilation system running through the entire room. The extraction is thus done at the level of the fume hoods as well as by a sheath. Blowing also takes place via a duct passing through each room. This laboratory being under construction, CFD numerical simulations were used here to help define the ventilation system to be implemented as well as to assess the comfort of the users of the room. The nature of the blowing duct (perforated duct or duct equipped with diffusers) was thus chosen according to the comfort criteria defined by the Fanger model or DR model (for Draft Rate). This model is based on a semi-empirical formulation to determine the percentage of people bothered by the airflow in a room. The performance of the ventilation system was also estimated according to the occupation of the premises and the activity in progress, in particular the opening or closing of the fume hoods.

Springer Link (Chiba Institute of Technology)
Openalex Percentile: Top 30%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

User comfort in a laboratory assessed though CFD simulation · Springer Link (Chiba Institute of Technology) (2025) | TGRS Research Map | TGRS