Effect of Infector’s location and occupants’ activity level on airborne spread in a gym – an experimental and CFD study

The airborne spread of pathogens in indoor environments, such as gyms, has gained significant importance due to its potential role in the transmission of infectious diseases. The presented study was performed in a gym setting equipped with a mixing ventilation system, spanning a floor area of 173.5 m2 (17.5m x 9.9m). Using a combination of computational simulations and field measurements, the investigation assessed the effect of source location with respect to exhaust on the distribution of airborne particles. This study also encompassed the effect of pathogens spread on two different levels of physical activities i.e., sedentary, and heavy. The findings were quantified using the local air quality index. The research revealed that when the sedentary contaminant source was positioned near the exhaust, there was a substantial reduction in the spread of contaminants, leading to higher values of the local air quality index, ranging between 0.1 – 5.5 as compared to the value of 0.1-1.2 when the source was farther away from the exhaust. It means when the source is near the return opening, the contaminants could be exhausted before they are fully mixed in the gym environment. For heavy physical activity, when there were increased breathing rates and higher heat gains associated with the occupants, the influence of the source’s location still exists, but there was a significant reduction in the local air quality index as compared to sedentary activity as the value was between 0.1 - 3.2 for the infector near the exhaust. The investigation emphasizes the need to account for physical activity levels when designing gym ventilation systems due to significantly higher contaminant spread during heavy activity. Additionally, the investigation has revealed the effect of injector location, particularly with respect to exhaust grille.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-12-05
DOI
https://doi.org/10.1051/e3sconf/202567207005/pdf
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Infector’s location and occupants’ activity level on airborne spread in a gym – an experimental and CFD study

Springer Link (Chiba Institute of Technology)
Infection Control and Ventilation
article

Effect of Infector’s location and occupants’ activity level on airborne spread in a gym – an experimental and CFD study

article en

Abstract

The airborne spread of pathogens in indoor environments, such as gyms, has gained significant importance due to its potential role in the transmission of infectious diseases. The presented study was performed in a gym setting equipped with a mixing ventilation system, spanning a floor area of 173.5 m2 (17.5m x 9.9m). Using a combination of computational simulations and field measurements, the investigation assessed the effect of source location with respect to exhaust on the distribution of airborne particles. This study also encompassed the effect of pathogens spread on two different levels of physical activities i.e., sedentary, and heavy. The findings were quantified using the local air quality index. The research revealed that when the sedentary contaminant source was positioned near the exhaust, there was a substantial reduction in the spread of contaminants, leading to higher values of the local air quality index, ranging between 0.1 – 5.5 as compared to the value of 0.1-1.2 when the source was farther away from the exhaust. It means when the source is near the return opening, the contaminants could be exhausted before they are fully mixed in the gym environment. For heavy physical activity, when there were increased breathing rates and higher heat gains associated with the occupants, the influence of the source’s location still exists, but there was a significant reduction in the local air quality index as compared to sedentary activity as the value was between 0.1 - 3.2 for the infector near the exhaust. The investigation emphasizes the need to account for physical activity levels when designing gym ventilation systems due to significantly higher contaminant spread during heavy activity. Additionally, the investigation has revealed the effect of injector location, particularly with respect to exhaust grille.

Springer Link (Chiba Institute of Technology)
Openalex Percentile: Top 30%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of Infector’s location and occupants’ activity level on airborne spread in a gym – an experimental and CFD study · Springer Link (Chiba Institute of Technology) (2025) | TGRS Research Map | TGRS