Airborne transmission of infectious diseases in rooms ventilated by mixing ventilation

This study aims to explore the parameters influencing the mixing level in rooms with mixing ventilation based on experimental results and CFD predictions. An increased concentration will be present close to sources in mixing ventilated rooms and almost fully mixed concentration will be found in some distance. In case of point sources, as an infected person, it will likewise give a distribution ranging from a high concentration in very close to face, down to a low concentration in the long distance in the room due to the turbulent mixing process and the fresh air supply. This distribution may change in the room when the point source change position, room temperature is changed, or the air supply rate is changed together with temperature. High ventilation rate is suggested for post-COVID ventilation design because it can provide a low concentration of pathogens. However, it often causes discomfort due to draught. In the last part of the study, we will compare five ventilation systems. We will identify conditions and systems that can handle high ventilation rate while minimizing draught rate.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-12-05
DOI
https://doi.org/10.1051/e3sconf/202567201022/pdf
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Airborne transmission of infectious diseases in rooms ventilated by mixing ventilation

Springer Link (Chiba Institute of Technology)
Infection Control and Ventilation
article

Airborne transmission of infectious diseases in rooms ventilated by mixing ventilation

article en

Abstract

This study aims to explore the parameters influencing the mixing level in rooms with mixing ventilation based on experimental results and CFD predictions. An increased concentration will be present close to sources in mixing ventilated rooms and almost fully mixed concentration will be found in some distance. In case of point sources, as an infected person, it will likewise give a distribution ranging from a high concentration in very close to face, down to a low concentration in the long distance in the room due to the turbulent mixing process and the fresh air supply. This distribution may change in the room when the point source change position, room temperature is changed, or the air supply rate is changed together with temperature. High ventilation rate is suggested for post-COVID ventilation design because it can provide a low concentration of pathogens. However, it often causes discomfort due to draught. In the last part of the study, we will compare five ventilation systems. We will identify conditions and systems that can handle high ventilation rate while minimizing draught rate.

Springer Link (Chiba Institute of Technology)
Openalex Percentile: Top 30%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.