Analysis of the input parameters for the infection risk model from CO

The COVID-19 pandemic has highlighted the importance of indoor air hygiene and understanding infection risk of pathogens. Ventilation rate, room dimensions and occupancy have remarkable effects on the infection risk at indoor spaces. Multiple sensor-based CO2 measurement enables continuous monitoring of the ventilation quality and the analysis of infection risk. This paper presents a practical case study of infection risk analysis in a classroom at different ventilation settings during lecture utilizing carbon dioxide sensors. The measurements consisted of 11 carbon dioxide sensors placed in different parts of the classroom. Three of the sensors were placed on the exhaust air valves of the room. The measurement situations were roughly two-hour lessons. A teacher and about 20 students were present during the lessons. In this case study, three different constant airflow settings were studied: 130 l/s, 200 l/s and 285 l/s. The infection risk model is based on the well-known Wells-Riley’s model. The input parameters such as ventilation flow rate and number of people in the classroom are analysed based on the CO2 measurements in the room. The ventilation rate has been estimated based on the CO2 decay rate after the finished lectures. CO2 decay rate is proportional to the ventilation rate and can be quantified based on the exponential decay model. The number of people in the classroom has been calculated based on the measured saturation CO2 concentration and the estimated CO2 emission rate per person. The results showed that the ventilation rate and occupancy in the classroom can be estimated based on the CO2 measurements and consequently this kind of real time monitoring can provide the needed parameters for automated during operation infection risk calculations.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-12-05
DOI
https://doi.org/10.1051/e3sconf/202567207003/pdf
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of the input parameters for the infection risk model from CO

Springer Link (Chiba Institute of Technology)
Infection Control and Ventilation
article

Analysis of the input parameters for the infection risk model from CO

article en

Abstract

The COVID-19 pandemic has highlighted the importance of indoor air hygiene and understanding infection risk of pathogens. Ventilation rate, room dimensions and occupancy have remarkable effects on the infection risk at indoor spaces. Multiple sensor-based CO2 measurement enables continuous monitoring of the ventilation quality and the analysis of infection risk. This paper presents a practical case study of infection risk analysis in a classroom at different ventilation settings during lecture utilizing carbon dioxide sensors. The measurements consisted of 11 carbon dioxide sensors placed in different parts of the classroom. Three of the sensors were placed on the exhaust air valves of the room. The measurement situations were roughly two-hour lessons. A teacher and about 20 students were present during the lessons. In this case study, three different constant airflow settings were studied: 130 l/s, 200 l/s and 285 l/s. The infection risk model is based on the well-known Wells-Riley’s model. The input parameters such as ventilation flow rate and number of people in the classroom are analysed based on the CO2 measurements in the room. The ventilation rate has been estimated based on the CO2 decay rate after the finished lectures. CO2 decay rate is proportional to the ventilation rate and can be quantified based on the exponential decay model. The number of people in the classroom has been calculated based on the measured saturation CO2 concentration and the estimated CO2 emission rate per person. The results showed that the ventilation rate and occupancy in the classroom can be estimated based on the CO2 measurements and consequently this kind of real time monitoring can provide the needed parameters for automated during operation infection risk calculations.

Springer Link (Chiba Institute of Technology)
Good health and well-being
Openalex Percentile: Top 30%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.