Assessment of thermal comfort at the building level: Evaluation of aggregation methods with a Danish case study of a campus building

Six methods for aggregating local thermal comfort scores in six offices to a single global score are investigated. using data collected by the building management system in a campus building of Aalborg University. Three static: 1) number of rooms weighted mean, 2) area-weighted mean, 3) desk-weighted mean, and three dynamic: 4) simple occupancy-weighted mean (PIR sensors), 5) advanced occupancy-weighted mean (PIR sensors mixed with the number of desks), 6) number of the occupants-weighted mean (camera readings). A notable disparity emerged between static methods, which rely solely on fixed parameters, and dynamic methods, which account for time-dependent factors over short timeframes. Dynamic methods consistently yielded lower global scores, irrespective of individual room performance. The difference can be up to 15% monthly. The PIR sensors, which are now commonly used in office or education buildings to control artificial lighting are a good indication of the occupancy (only present and not present). The information on number of occupants in the offices, collected by installed cameras, did not provide significantly better results in the analysed case study.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-12-05
DOI
https://doi.org/10.1051/e3sconf/202567201057/pdf
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of thermal comfort at the building level: Evaluation of aggregation methods with a Danish case study of a campus building

Springer Link (Chiba Institute of Technology)
Building Energy and Comfort Optimization
article

Assessment of thermal comfort at the building level: Evaluation of aggregation methods with a Danish case study of a campus building

article en

Abstract

Six methods for aggregating local thermal comfort scores in six offices to a single global score are investigated. using data collected by the building management system in a campus building of Aalborg University. Three static: 1) number of rooms weighted mean, 2) area-weighted mean, 3) desk-weighted mean, and three dynamic: 4) simple occupancy-weighted mean (PIR sensors), 5) advanced occupancy-weighted mean (PIR sensors mixed with the number of desks), 6) number of the occupants-weighted mean (camera readings). A notable disparity emerged between static methods, which rely solely on fixed parameters, and dynamic methods, which account for time-dependent factors over short timeframes. Dynamic methods consistently yielded lower global scores, irrespective of individual room performance. The difference can be up to 15% monthly. The PIR sensors, which are now commonly used in office or education buildings to control artificial lighting are a good indication of the occupancy (only present and not present). The information on number of occupants in the offices, collected by installed cameras, did not provide significantly better results in the analysed case study.

Springer Link (Chiba Institute of Technology)
Quality Education
Openalex Percentile: Top 43%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.