Feasibility of using mobile air cleaners in school classrooms to remove respiratory aerosols

To investigate the feasibility of using mobile air cleaners (MACs) in school classrooms for reducing respiratory aerosols, a test on aerosol removal of seven different types of MACs was conducted in a university classroom, for the optimal condition determined by a prior experimental study. Most of the MACs achieved a good level of clean air delivery rate (CADR) (900-1000 m3/h), and the CADR increased with the number of devices used. Based on the results, three MACs were further selected for conducting an ongoing field study in 45 classrooms at five Dutch primary schools. Each classroom was assigned one type of MAC with two devices, and was monitored for a period of six weeks with three weeks the devices turned on and three weeks off. The assessments of feasibility are based on measurements of indoor air quality, information on absenteeism of the pupils, and interviews with the occupants. The results are yet to be collected to draw further conclusions. However, problems were already encountered during the installation process of the devices which hindered the realization of the pre-determined strategies.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-12-05
DOI
https://doi.org/10.1051/e3sconf/202567201013/pdf
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility of using mobile air cleaners in school classrooms to remove respiratory aerosols

Springer Link (Chiba Institute of Technology)
Indoor Air Quality and Microbial Exposure
article

Feasibility of using mobile air cleaners in school classrooms to remove respiratory aerosols

article en

Abstract

To investigate the feasibility of using mobile air cleaners (MACs) in school classrooms for reducing respiratory aerosols, a test on aerosol removal of seven different types of MACs was conducted in a university classroom, for the optimal condition determined by a prior experimental study. Most of the MACs achieved a good level of clean air delivery rate (CADR) (900-1000 m3/h), and the CADR increased with the number of devices used. Based on the results, three MACs were further selected for conducting an ongoing field study in 45 classrooms at five Dutch primary schools. Each classroom was assigned one type of MAC with two devices, and was monitored for a period of six weeks with three weeks the devices turned on and three weeks off. The assessments of feasibility are based on measurements of indoor air quality, information on absenteeism of the pupils, and interviews with the occupants. The results are yet to be collected to draw further conclusions. However, problems were already encountered during the installation process of the devices which hindered the realization of the pre-determined strategies.

Springer Link (Chiba Institute of Technology)
Quality Education
Openalex Percentile: Top 35%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Feasibility of using mobile air cleaners in school classrooms to remove respiratory aerosols · Springer Link (Chiba Institute of Technology) (2025) | TGRS Research Map | TGRS