The impact of inlet and obstacle conditions on the indoor environment with impinging jet ventilation system

The impinging jet ventilation system (IJV) is drawing people’s attention due to its high ventilation effectiveness and applicability to various situations. In IJV, the fresh air is supplied downward and moves along the floor until it reaches the heat and contaminant source; finally, it is exhausted around the ceiling. Because of this ventilation strategy, temperature and contaminant concentration profiles stratify vertically, so that the effectiveness of temperature and ventilation is kept high within the occupied zone. However, in practice, there can be some obstacles on the floor that might have some impact on the indoor environment. To investigate this impact, the experiments were conducted in a full-scale experimental chamber under cooling conditions in summer. To simulate a small office room, one supply inlet duct, four seated human simulators and four PC simulators are distributed within the room as heat sources. The human simulators released the contaminant from their mouth as well. The thermal environment and ventilation effectiveness were evaluated, and it was shown that the effect of cabinet on the indoor environment differed depending on the supply conditions.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-12-05
DOI
https://doi.org/10.1051/e3sconf/202567201039/pdf
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The impact of inlet and obstacle conditions on the indoor environment with impinging jet ventilation system

Springer Link (Chiba Institute of Technology)
Infection Control and Ventilation
article

The impact of inlet and obstacle conditions on the indoor environment with impinging jet ventilation system

article en

Abstract

The impinging jet ventilation system (IJV) is drawing people’s attention due to its high ventilation effectiveness and applicability to various situations. In IJV, the fresh air is supplied downward and moves along the floor until it reaches the heat and contaminant source; finally, it is exhausted around the ceiling. Because of this ventilation strategy, temperature and contaminant concentration profiles stratify vertically, so that the effectiveness of temperature and ventilation is kept high within the occupied zone. However, in practice, there can be some obstacles on the floor that might have some impact on the indoor environment. To investigate this impact, the experiments were conducted in a full-scale experimental chamber under cooling conditions in summer. To simulate a small office room, one supply inlet duct, four seated human simulators and four PC simulators are distributed within the room as heat sources. The human simulators released the contaminant from their mouth as well. The thermal environment and ventilation effectiveness were evaluated, and it was shown that the effect of cabinet on the indoor environment differed depending on the supply conditions.

Springer Link (Chiba Institute of Technology)
Openalex Percentile: Top 30%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.