FAST-AIR: Fast analytic systems for tracer-gas assessment in indoor research - development and testing of CO

The time constant of ventilation of rooms in buildings is between 15 minutes (in office spaces) to 2 hours (in residential buildings). Currently, most of the tracer gas system analyzers on the market have a minute-based time constant and depending on the channels a cycle of sampling and analysis may take up to 6 minutes, E.g., 6 channel system. Essentially, only mean values are recorded with most present tracer gas analyzers. This is a hindrance for detailed temporal analysis of conditions in the room and consequently is does not capture the resolution of the influence of the internal flow on air and contaminant distribution. The current paper presents work on the development and testing of a fast response CO2 tracer-gas system with a time constant of 1 second. In contrast to the present analyzers, not only the mean values but also the whole statistical distribution of variables can be recorded, and pulse responses can be analyzed. This makes the system viable for measurement and analysis of not only spatial but also temporal distribution of contaminants. For example, recirculating airflow in the room generated by flooding of ventilation air is possible to be measured and thus making it easy to extend the analyses of the process of ventilation far beyond the possibilities with current systems.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-12-05
DOI
https://doi.org/10.1051/e3sconf/202567202007/pdf
Primary Topic
Wind and Air Flow Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

FAST-AIR: Fast analytic systems for tracer-gas assessment in indoor research - development and testing of CO

Springer Link (Chiba Institute of Technology)
Wind and Air Flow Studies
article

FAST-AIR: Fast analytic systems for tracer-gas assessment in indoor research - development and testing of CO

article en

Abstract

The time constant of ventilation of rooms in buildings is between 15 minutes (in office spaces) to 2 hours (in residential buildings). Currently, most of the tracer gas system analyzers on the market have a minute-based time constant and depending on the channels a cycle of sampling and analysis may take up to 6 minutes, E.g., 6 channel system. Essentially, only mean values are recorded with most present tracer gas analyzers. This is a hindrance for detailed temporal analysis of conditions in the room and consequently is does not capture the resolution of the influence of the internal flow on air and contaminant distribution. The current paper presents work on the development and testing of a fast response CO2 tracer-gas system with a time constant of 1 second. In contrast to the present analyzers, not only the mean values but also the whole statistical distribution of variables can be recorded, and pulse responses can be analyzed. This makes the system viable for measurement and analysis of not only spatial but also temporal distribution of contaminants. For example, recirculating airflow in the room generated by flooding of ventilation air is possible to be measured and thus making it easy to extend the analyses of the process of ventilation far beyond the possibilities with current systems.

Springer Link (Chiba Institute of Technology)
Sustainable cities and communities
Openalex Percentile: Top 45%
Wind and Air Flow Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.