Combining perforated ceiling and attic ventilation for night cooling in a single-zone building: CFD analysis

The ventilative cooling potential of a perforated ceiling in combination with attic ventilation during the night in naturally ventilated residential buildings in tropical climate is investigated. 3D steady Reynolds-averaged Navier-Stokes (RANS) computational fluid dynamics (CFD) simulations were carried out with the RNG k-ε turbulence model under non-isothermal conditions for two different single zone realistic building models, C1 (building without perforated ceiling and attic ventilation) and C2 (with perforated ceiling (40% porosity) and attic ventilation). The simulations were conducted for nighttime conditions in Indonesia (Makassar), as obtained from measured weather data, to represent real-life conditions as much as possible. The CFD simulations were performed for the wind direction perpendicular to the building facade with the window openings. The heat removal effectiveness (HRE) and air changes per hour (ACH) were assessed for both building configurations. The results show that building C2 facilitates a faster removal of heat from the occupied zone compared to building C1. This leads to a reduction of indoor air temperature that is lower by 0.8 °C for case C2 compared to case C1. Moreover, C2 displays higher values for both HRE (1.25 vs. 1.00) and ACH (34.1 h-1 vs. 27.9 h-1).

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-12-05
DOI
https://doi.org/10.1051/e3sconf/202567207034/pdf
Primary Topic
Wind and Air Flow Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Combining perforated ceiling and attic ventilation for night cooling in a single-zone building: CFD analysis

Springer Link (Chiba Institute of Technology)
Wind and Air Flow Studies
article

Combining perforated ceiling and attic ventilation for night cooling in a single-zone building: CFD analysis

article en

Abstract

The ventilative cooling potential of a perforated ceiling in combination with attic ventilation during the night in naturally ventilated residential buildings in tropical climate is investigated. 3D steady Reynolds-averaged Navier-Stokes (RANS) computational fluid dynamics (CFD) simulations were carried out with the RNG k-ε turbulence model under non-isothermal conditions for two different single zone realistic building models, C1 (building without perforated ceiling and attic ventilation) and C2 (with perforated ceiling (40% porosity) and attic ventilation). The simulations were conducted for nighttime conditions in Indonesia (Makassar), as obtained from measured weather data, to represent real-life conditions as much as possible. The CFD simulations were performed for the wind direction perpendicular to the building facade with the window openings. The heat removal effectiveness (HRE) and air changes per hour (ACH) were assessed for both building configurations. The results show that building C2 facilitates a faster removal of heat from the occupied zone compared to building C1. This leads to a reduction of indoor air temperature that is lower by 0.8 °C for case C2 compared to case C1. Moreover, C2 displays higher values for both HRE (1.25 vs. 1.00) and ACH (34.1 h-1 vs. 27.9 h-1).

Springer Link (Chiba Institute of Technology)
Climate action
Openalex Percentile: Top 45%
Wind and Air Flow Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.