S5327 High-Power Argon Plasma Coagulation for Cutting Embedded Biliary Metal Stents in Ascending Cholangitis: A Life-Saving Endoscopic Strategy!

Introduction: When an uncovered (UMS) or partially covered metal stent (PCMS) becomes occluded and migrates deeply into the third portion of the duodenum, while remaining in the distal bile duct, removal and retrograde biliary access become nearly impossible. In such scenarios, trimming the stent to the level of the ampulla is a viable method to restore access. We present a fast and safe technique for cutting 2 biliary metal stents (in a stent-in-stent configuration) using high-power argon plasma coagulation (APC) with a forward-viewing gastroscope. Case Description: A 72-year-old man with subacute painless jaundice and a pancreatic head mass with liver metastases underwent initial ERCP with placement of an uncovered metal stent. Pathology confirmed lymphoma. A second ERCP placed a fully covered metal stent inside the original. The patient later developed ascending cholangitis due to obstruction and partial migration of both stents into the third portion of the duodenum. Proximal ends remained in the mid-bile duct, making removal and retrograde access impossible. High-power APC (80-100 W, 1.5 L/min gas flow) was used to trim the stents. The procedure took 25 minutes with no complications. Discussion: Managing complications caused by embedded or migrated UMS or PCMS—including cholangitis, duodenal bleeding, or perforation—is difficult, with few endoscopic options. High-power APC is a safe and efficient method to trim exposed metal stents, allowing for retrograde biliary access. This approach enables balloon sweeping and placement of plastic stents within the remaining metal stents, restoring patency and reducing the risk of further complications. High-setting APC (80-100 W, gas flow 0.8-1.5 L/min) is a fast, effective, and minimally invasive strategy for cutting obstructed, embedded, or migrated biliary metal stents. It provides life-saving access for managing ascending cholangitis and other complications. This widely available technique should be considered an essential tool in the therapeutic biliary endoscopist’s armamentarium.

Publication Details

Journal
The American Journal of Gastroenterology
Published
2025-10-01
DOI
https://doi.org/10.14309/01.ajg.0001148768.21477.21
Primary Topic
Gallbladder and Bile Duct Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

S5327 High-Power Argon Plasma Coagulation for Cutting Embedded Biliary Metal Stents in Ascending Cholangitis: A Life-Saving Endoscopic Strategy!

The American Journal of Gastroenterology
Gallbladder and Bile Duct Disorders
article

S5327 High-Power Argon Plasma Coagulation for Cutting Embedded Biliary Metal Stents in Ascending Cholangitis: A Life-Saving Endoscopic Strategy!

article en

Abstract

Introduction: When an uncovered (UMS) or partially covered metal stent (PCMS) becomes occluded and migrates deeply into the third portion of the duodenum, while remaining in the distal bile duct, removal and retrograde biliary access become nearly impossible. In such scenarios, trimming the stent to the level of the ampulla is a viable method to restore access. We present a fast and safe technique for cutting 2 biliary metal stents (in a stent-in-stent configuration) using high-power argon plasma coagulation (APC) with a forward-viewing gastroscope. Case Description: A 72-year-old man with subacute painless jaundice and a pancreatic head mass with liver metastases underwent initial ERCP with placement of an uncovered metal stent. Pathology confirmed lymphoma. A second ERCP placed a fully covered metal stent inside the original. The patient later developed ascending cholangitis due to obstruction and partial migration of both stents into the third portion of the duodenum. Proximal ends remained in the mid-bile duct, making removal and retrograde access impossible. High-power APC (80-100 W, 1.5 L/min gas flow) was used to trim the stents. The procedure took 25 minutes with no complications. Discussion: Managing complications caused by embedded or migrated UMS or PCMS—including cholangitis, duodenal bleeding, or perforation—is difficult, with few endoscopic options. High-power APC is a safe and efficient method to trim exposed metal stents, allowing for retrograde biliary access. This approach enables balloon sweeping and placement of plastic stents within the remaining metal stents, restoring patency and reducing the risk of further complications. High-setting APC (80-100 W, gas flow 0.8-1.5 L/min) is a fast, effective, and minimally invasive strategy for cutting obstructed, embedded, or migrated biliary metal stents. It provides life-saving access for managing ascending cholangitis and other complications. This widely available technique should be considered an essential tool in the therapeutic biliary endoscopist’s armamentarium.

The American Journal of GastroenterologyVol. 120(10S2)
Responsible consumption and production
Openalex Percentile: Top 30%
Gallbladder and Bile Duct Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

S5327 High-Power Argon Plasma Coagulation for Cutting Embedded Biliary Metal Stents in Ascending Cholangitis: A Life-Saving Endoscopic Strategy! · The American Journal of Gastroenterology (2025) | TGRS Research Map | TGRS