Impacts of ventilation designs on airborne particle transportation

This study aimed to evaluate impacts of ventilation designs on indoor airborne transmission for mixing ventilation (MV) focusing on ventilation effectivness. Different flow rates (8 to 40 l/s), exhaust positions (high and low), source locations and effects of air cleaning were tested, and particle concentrations with different size fractions were measured. The results showed that the ventilation effectiveness was decreased with an increased flow rate, which was reduced from about 1.15 (with 8 l/s) to 0.9 (with 40 l/s) for a standard MV configuration. With 30 l/s the effectiveness was about 1. This trend was due to stratification with low flow rates and short-circuit related to high flow rates. Although lower flow rates showed greater ventilation effectivness at the compared locations, higher flow rates would always provide better dilution. This suggested that a balance between the contaminant dilution and removal should be considered when increasing flow rates to enable sufficient and effective ventilation. Moving the exhaust from the ceiling to floor level was less effective due to short-circuit. Placing the source close to, and under the exhaust helped to remove contaminants more efficiently. Air cleaning added significant impacts on ventilation to reduce particles for the supply flow rate of 15 l/s.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-12-05
DOI
https://doi.org/10.1051/e3sconf/202567201027/pdf
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impacts of ventilation designs on airborne particle transportation

Springer Link (Chiba Institute of Technology)
Infection Control and Ventilation
article

Impacts of ventilation designs on airborne particle transportation

article en

Abstract

This study aimed to evaluate impacts of ventilation designs on indoor airborne transmission for mixing ventilation (MV) focusing on ventilation effectivness. Different flow rates (8 to 40 l/s), exhaust positions (high and low), source locations and effects of air cleaning were tested, and particle concentrations with different size fractions were measured. The results showed that the ventilation effectiveness was decreased with an increased flow rate, which was reduced from about 1.15 (with 8 l/s) to 0.9 (with 40 l/s) for a standard MV configuration. With 30 l/s the effectiveness was about 1. This trend was due to stratification with low flow rates and short-circuit related to high flow rates. Although lower flow rates showed greater ventilation effectivness at the compared locations, higher flow rates would always provide better dilution. This suggested that a balance between the contaminant dilution and removal should be considered when increasing flow rates to enable sufficient and effective ventilation. Moving the exhaust from the ceiling to floor level was less effective due to short-circuit. Placing the source close to, and under the exhaust helped to remove contaminants more efficiently. Air cleaning added significant impacts on ventilation to reduce particles for the supply flow rate of 15 l/s.

Springer Link (Chiba Institute of Technology)
Openalex Percentile: Top 30%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.