Performance of Concrete Mixed with Non-Potable Water Sources: A Compressive Strength Investigation

With growing concern over freshwater scarcity, this study explores the feasibility of using non-conventional water sources rainwater, underground water, mosque wastewater, and agricultural runoff as alternatives to potable water in concrete mixing. Five types of water were sourced locally and used in concrete mixtures designed using the ACI 211.1- 91 method with a constant water-to-cement ratio of 0.475. A total of 45 cylindrical specimens were tested for compressive strength at curing ages of 7, 14, and 28 days. The control mix using potable water achieved the highest 28-day strength (16.3 MPa), while concrete made with mosque wastewater and underground water reached 15.2 MPa and 14.7 MPa, respectively, demonstrating strong performance. Agricultural runoff showed acceptable results (14.1 MPa), suitable for non-critical applications. Rainwater, however, resulted in the lowest strength (8.5 MPa at 28 days), indicating potential issues with its chemical composition. The findings suggest that mosque wastewater and underground water are promising substitutes for structural-grade concrete, offering sustainable water reuse options in construction. This study provides practical insights for implementing alternative water strategies in water-scarce regions and underscores the need for further chemical and durability evaluations to support broader application.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-12-05
DOI
https://doi.org/10.1051/bioconf/202519905005/pdf
Primary Topic
Urban Stormwater Management Solutions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance of Concrete Mixed with Non-Potable Water Sources: A Compressive Strength Investigation

Springer Link (Chiba Institute of Technology)
Urban Stormwater Management Solutions
article

Performance of Concrete Mixed with Non-Potable Water Sources: A Compressive Strength Investigation

article en

Abstract

With growing concern over freshwater scarcity, this study explores the feasibility of using non-conventional water sources rainwater, underground water, mosque wastewater, and agricultural runoff as alternatives to potable water in concrete mixing. Five types of water were sourced locally and used in concrete mixtures designed using the ACI 211.1- 91 method with a constant water-to-cement ratio of 0.475. A total of 45 cylindrical specimens were tested for compressive strength at curing ages of 7, 14, and 28 days. The control mix using potable water achieved the highest 28-day strength (16.3 MPa), while concrete made with mosque wastewater and underground water reached 15.2 MPa and 14.7 MPa, respectively, demonstrating strong performance. Agricultural runoff showed acceptable results (14.1 MPa), suitable for non-critical applications. Rainwater, however, resulted in the lowest strength (8.5 MPa at 28 days), indicating potential issues with its chemical composition. The findings suggest that mosque wastewater and underground water are promising substitutes for structural-grade concrete, offering sustainable water reuse options in construction. This study provides practical insights for implementing alternative water strategies in water-scarce regions and underscores the need for further chemical and durability evaluations to support broader application.

Springer Link (Chiba Institute of Technology)
Openalex Percentile: Top 45%
Urban Stormwater Management Solutions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.