Effects of grout-strand interface modelling on the degradation of external grouted post-tensioning tendons

In recent years, relevant brittle fractures of external grouted post-tensioning tendons in bridges have been reported due to corrosion damage, compromising the structural safety and stability of the bridges. A previous detailed finite element (FE) modelling approach for grouted tendons has been developed by the authors and compared with experimental results presented in the literature, ensuring an accurate reproduction of experimental results by accounting for steel plasticity and large deformations. This modelling approach considered a bonded contact to model the strand-grout interface. That is, an immediate re-anchoring of the strands in the grout is assumed in case of failure and, consequently the influence of the bond stress-slip behaviour is not considered in the modelling approach. This paper presents an alternative FE modelling strategy where the differences with the previous one are: i) the modelling of the strands as beams instead of solid bodies, ii) the presence of the sheathing duct, and iii) a non-linear model to reproduce the strand-grout bond stress-slip behaviour. The objective is to investigate the influence of different models to define the grout-strand interface: a bonded model or a bond stress-slip model, while validating the author’s previous FE approach. These models are also compared with the experimental results from the literature. Normal stresses along the strands and in the grout are studied, and degradation curves are derived, that is, the effective tensile force and natural frequencies versus damage (defined as the percentage of broken strands). These degradation curves serve as a key performance indicator of the structural performance of the tendon for structural health monitoring systems, anticipating to severe damage and potentially dangerous scenarios.

Publication Details

Journal
UPM Digital Archive (Technical University of Madrid)
Published
2025-09-01
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of grout-strand interface modelling on the degradation of external grouted post-tensioning tendons

UPM Digital Archive (Technical University of Madrid)
Structural Behavior of Reinforced Concrete
article

Effects of grout-strand interface modelling on the degradation of external grouted post-tensioning tendons

article en

Abstract

In recent years, relevant brittle fractures of external grouted post-tensioning tendons in bridges have been reported due to corrosion damage, compromising the structural safety and stability of the bridges. A previous detailed finite element (FE) modelling approach for grouted tendons has been developed by the authors and compared with experimental results presented in the literature, ensuring an accurate reproduction of experimental results by accounting for steel plasticity and large deformations. This modelling approach considered a bonded contact to model the strand-grout interface. That is, an immediate re-anchoring of the strands in the grout is assumed in case of failure and, consequently the influence of the bond stress-slip behaviour is not considered in the modelling approach. This paper presents an alternative FE modelling strategy where the differences with the previous one are: i) the modelling of the strands as beams instead of solid bodies, ii) the presence of the sheathing duct, and iii) a non-linear model to reproduce the strand-grout bond stress-slip behaviour. The objective is to investigate the influence of different models to define the grout-strand interface: a bonded model or a bond stress-slip model, while validating the author’s previous FE approach. These models are also compared with the experimental results from the literature. Normal stresses along the strands and in the grout are studied, and degradation curves are derived, that is, the effective tensile force and natural frequencies versus damage (defined as the percentage of broken strands). These degradation curves serve as a key performance indicator of the structural performance of the tendon for structural health monitoring systems, anticipating to severe damage and potentially dangerous scenarios.

UPM Digital Archive (Technical University of Madrid)
Openalex Percentile: Top 43%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effects of grout-strand interface modelling on the degradation of external grouted post-tensioning tendons · UPM Digital Archive (Technical University of Madrid) (2025) | TGRS Research Map | TGRS