Clinical Tolerance to Induced Astigmatism in Eyes Implanted with a Single Extended Depth of Focus Intraocular Lens (AT LARA®)

Wilson Takashi Hida,1 Bernardo Kaplan Moscovici,2– 4 Paulo Eduardo Souto Castro Miziara,1 Daniel Cruz Nogueira,1 Cesar Vilar,1,5 Danilo Varela Kniggendorf,1 Patrick Frensel De Moraes Tzelikis,1 Leandro P Mundim,1 Irineu Ribeiro de Melo Junior,1 André Lins De Medeiros,1 Walton Nose,2 Pedro C Carricondo6 1Department of Ophthalmology, Hospital Oftalmológico de Brasília, Brasília, DF, Brazil; 2Department of Ophthalmology, Federal University of São Paulo (UNIFESP), São Paulo, SP, Brazil; 3Department of Ophthalmology, Hospital Visão Laser, Santos, SP, Brazil; 4Postgraduate Program in Translational Medicine, Escola Paulista de Medicina, Federal University of São Paulo (UNIFESP), São Paulo, SP, Brazil; 5Vilar Hospital de Olhos, Teresina, PI, Brazil; 6Department of Ophthalmology, University of São Paulo, São Paulo, SP, BrazilCorrespondence: Bernardo Kaplan Moscovici, Department of Ophthalmology, Federal University of São Paulo (UNIFESP), Rua Cayowaa, 854, apt. 82, São Paulo, SP, 05018-001, Brazil, Email [email protected]: To evaluate clinical tolerance to induced astigmatism in pseudophakic eyes bilaterally implanted with an extended depth of focus (EDOF) intraocular lens (AT LARA®, Carl Zeiss Meditec). We hypothesized that small amounts of induced astigmatism may be clinically well tolerated by patients implanted with this EDOF IOL.Methods: Prospective study including 10 patients (20 eyes) bilaterally implanted with the same EDOF IOL. Monocular defocus curves were obtained under photopic conditions after introducing cylindrical lenses of +1.00 D, +2.00 D, and +3.00 D at with-the-rule (WTR) and against-the-rule (ATR) orientations.Results: The IOL demonstrated good tolerance up to +1.00 D of induced astigmatism, with significant reductions in visual acuity at higher magnitudes of astigmatism. Tolerance was higher for ATR astigmatism compared to WTR, consistent with axis-dependent depth-of-focus effects.Conclusion: The AT LARA® EDOF IOL maintained functional visual performance with up to +1.00 D of regular astigmatism, while higher magnitudes led to clinically meaningful degradation. Axis orientation modulated performance, with ATR preserving intermediate and near vision and WTR favoring distance.Keywords: extended depth of focus intraocular lens, pseudophakia, astigmatism tolerance, defocus curve, with-the-rule, against-the-rule, toric intraocular lens

Publication Details

Journal
Dove Medical Press (Taylor and Francis Group)
Published
2025-12-05
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical Tolerance to Induced Astigmatism in Eyes Implanted with a Single Extended Depth of Focus Intraocular Lens (AT LARA®)

Dove Medical Press (Taylor and Francis Group)
Ophthalmology and Visual Impairment Studies
article

Clinical Tolerance to Induced Astigmatism in Eyes Implanted with a Single Extended Depth of Focus Intraocular Lens (AT LARA®)

article en

Abstract

Wilson Takashi Hida,1 Bernardo Kaplan Moscovici,2– 4 Paulo Eduardo Souto Castro Miziara,1 Daniel Cruz Nogueira,1 Cesar Vilar,1,5 Danilo Varela Kniggendorf,1 Patrick Frensel De Moraes Tzelikis,1 Leandro P Mundim,1 Irineu Ribeiro de Melo Junior,1 André Lins De Medeiros,1 Walton Nose,2 Pedro C Carricondo6 1Department of Ophthalmology, Hospital Oftalmológico de Brasília, Brasília, DF, Brazil; 2Department of Ophthalmology, Federal University of São Paulo (UNIFESP), São Paulo, SP, Brazil; 3Department of Ophthalmology, Hospital Visão Laser, Santos, SP, Brazil; 4Postgraduate Program in Translational Medicine, Escola Paulista de Medicina, Federal University of São Paulo (UNIFESP), São Paulo, SP, Brazil; 5Vilar Hospital de Olhos, Teresina, PI, Brazil; 6Department of Ophthalmology, University of São Paulo, São Paulo, SP, BrazilCorrespondence: Bernardo Kaplan Moscovici, Department of Ophthalmology, Federal University of São Paulo (UNIFESP), Rua Cayowaa, 854, apt. 82, São Paulo, SP, 05018-001, Brazil, Email [email protected]: To evaluate clinical tolerance to induced astigmatism in pseudophakic eyes bilaterally implanted with an extended depth of focus (EDOF) intraocular lens (AT LARA®, Carl Zeiss Meditec). We hypothesized that small amounts of induced astigmatism may be clinically well tolerated by patients implanted with this EDOF IOL.Methods: Prospective study including 10 patients (20 eyes) bilaterally implanted with the same EDOF IOL. Monocular defocus curves were obtained under photopic conditions after introducing cylindrical lenses of +1.00 D, +2.00 D, and +3.00 D at with-the-rule (WTR) and against-the-rule (ATR) orientations.Results: The IOL demonstrated good tolerance up to +1.00 D of induced astigmatism, with significant reductions in visual acuity at higher magnitudes of astigmatism. Tolerance was higher for ATR astigmatism compared to WTR, consistent with axis-dependent depth-of-focus effects.Conclusion: The AT LARA® EDOF IOL maintained functional visual performance with up to +1.00 D of regular astigmatism, while higher magnitudes led to clinically meaningful degradation. Axis orientation modulated performance, with ATR preserving intermediate and near vision and WTR favoring distance.Keywords: extended depth of focus intraocular lens, pseudophakia, astigmatism tolerance, defocus curve, with-the-rule, against-the-rule, toric intraocular lens

Dove Medical Press (Taylor and Francis Group)
Openalex Percentile: Top 32%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Clinical Tolerance to Induced Astigmatism in Eyes Implanted with a Single Extended Depth of Focus Intraocular Lens (AT LARA®) · Dove Medical Press (Taylor and Francis Group) (2025) | TGRS Research Map | TGRS