Численное исследование течения и теплообмена при термогравитационной конвекции воздуха в однорядном пучке горизонтальных оребренных труб

The results of numerical modeling of airflow and heat transfer in a horizontally oriented single-row bundle consisting of six finned heated tubes under thermogravitational conditions are pre- sented. The study is performed for the bundles with a compact tube arrangement and varying fin pitch. The cases without and with the rectangular exhaust shafts of different heights installed above the bundle have been investigated. For the most compact bundle configuration in the absence of a shaft in the con- sidered range of moderate values of the Grashof number (up to 5.5×105), a good agreement was obtained between the calculated integral Nusselt number at the tube surface and experimental data taken from the literature. The combination of the fin pitch (spatial arrangement on the tubes) and the shaft height determined in computations allowed to obtain the optimal bundle design with the highest intensity of heat removal

Publication Details

Journal
SibFU Digital Repository (Siberian Federal University)
Published
2025-12-04
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Численное исследование течения и теплообмена при термогравитационной конвекции воздуха в однорядном пучке горизонтальных оребренных труб

SibFU Digital Repository (Siberian Federal University)
Heat Transfer and Optimization
article

Численное исследование течения и теплообмена при термогравитационной конвекции воздуха в однорядном пучке горизонтальных оребренных труб

article en

Abstract

The results of numerical modeling of airflow and heat transfer in a horizontally oriented single-row bundle consisting of six finned heated tubes under thermogravitational conditions are pre- sented. The study is performed for the bundles with a compact tube arrangement and varying fin pitch. The cases without and with the rectangular exhaust shafts of different heights installed above the bundle have been investigated. For the most compact bundle configuration in the absence of a shaft in the con- sidered range of moderate values of the Grashof number (up to 5.5×105), a good agreement was obtained between the calculated integral Nusselt number at the tube surface and experimental data taken from the literature. The combination of the fin pitch (spatial arrangement on the tubes) and the shaft height determined in computations allowed to obtain the optimal bundle design with the highest intensity of heat removal

SibFU Digital Repository (Siberian Federal University)
Openalex Percentile: Top 47%
Heat Transfer and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.