Spatially Resolved Parameter-Measurement of Oxygen ICP via Optical Emission Spectroscopy with Tomographic Analysis

Optical Emission Spectroscopy (OES) combined with tomographic analysis was used to measure spatial distributions of plasma radiance in oxygen inductively coupled plasma (ICP). From the reconstructed radiance profiles, the dissociation degree of oxygen molecules was estimated using actinometry. These results were then applied to a Collisional-Radiative Model (CRM) to calculate spatial distributions of electron temperature and electron density. The combined use of tomographic OES, actinometric analysis, and CRM enabled a detailed, spatially resolved characterization of oxygen plasma parameters under ICP power conditions of 400-800 W and pressure conditions of 1-10 Pa.

Publication Details

Journal
Tokyo Tech Research Repository (Tokyo Institute of Technology)
Published
2025-10-14
Primary Topic
Plasma Diagnostics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spatially Resolved Parameter-Measurement of Oxygen ICP via Optical Emission Spectroscopy with Tomographic Analysis

Tokyo Tech Research Repository (Tokyo Institute of Technology)
Plasma Diagnostics and Applications
article

Spatially Resolved Parameter-Measurement of Oxygen ICP via Optical Emission Spectroscopy with Tomographic Analysis

article en

Abstract

Optical Emission Spectroscopy (OES) combined with tomographic analysis was used to measure spatial distributions of plasma radiance in oxygen inductively coupled plasma (ICP). From the reconstructed radiance profiles, the dissociation degree of oxygen molecules was estimated using actinometry. These results were then applied to a Collisional-Radiative Model (CRM) to calculate spatial distributions of electron temperature and electron density. The combined use of tomographic OES, actinometric analysis, and CRM enabled a detailed, spatially resolved characterization of oxygen plasma parameters under ICP power conditions of 400-800 W and pressure conditions of 1-10 Pa.

Tokyo Tech Research Repository (Tokyo Institute of Technology)
Openalex Percentile: Top 44%
Plasma Diagnostics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Spatially Resolved Parameter-Measurement of Oxygen ICP via Optical Emission Spectroscopy with Tomographic Analysis · Tokyo Tech Research Repository (Tokyo Institute of Technology) (2025) | TGRS Research Map | TGRS