Реалізація чергованого двонаправленого постійно-постійного перетворювача з багатоступеневим заряджанням постійним струмом на основі нечіткого керування для стійких до перешкод станцій заміни акумуляторів електромобілів

This research presents an interleaved bi-directional non-inverting buck-boost converter designed for public electric vehicle battery swapping stations (BSS). This study solves the critical problem of BSS vulnerability to main power outages, which threatens their operational reliability. The developed solution is a device that not only performs efficient charging but also functions as an emergency power source, utilizing power from connected batteries during a grid failure. The methodology incorporates an interleaved topology and a multi-stage constant current (MSCC) charging method controlled by a fuzzy logic controller (FLC). Experimental results show the interleaved operation successfully increased power capacity up to 1.1 kW, achieving an average efficiency of 93.44%. A distinctive feature of the result is the reduction of the output current ripple by 47.7% down to 0.92%. This is explained by the ripple-cancellation effect inherent to the interleaved design, which is a key feature for preserving long-term battery health. Furthermore, the MSCC method achieved a 13.7% reduction in execution time compared to the conventional constant current-constant voltage (CC-CV) method, with a total charging duration of 66.8 minutes. This validated prototype successfully demonstrated a seamless and automatic emergency mode transition during a power failure, directly answering the BSS reliability challenge. The prototype also confirmed its bidirectional functionality and seamless mode transition from standard charging to emergency power supply mode. The scope of this research provides a practical and high-performance integrated solution for BSS, effectively addressing vulnerability issues by improving reliability and charging time efficiency, ensuring continuous service.

Publication Details

Journal
The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Published
2025-10-31
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Реалізація чергованого двонаправленого постійно-постійного перетворювача з багатоступеневим заряджанням постійним струмом на основі нечіткого керування для стійких до перешкод станцій заміни акумуляторів електромобілів

The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Advanced Battery Technologies Research
article

Реалізація чергованого двонаправленого постійно-постійного перетворювача з багатоступеневим заряджанням постійним струмом на основі нечіткого керування для стійких до перешкод станцій заміни акумуляторів електромобілів

article en

Abstract

This research presents an interleaved bi-directional non-inverting buck-boost converter designed for public electric vehicle battery swapping stations (BSS). This study solves the critical problem of BSS vulnerability to main power outages, which threatens their operational reliability. The developed solution is a device that not only performs efficient charging but also functions as an emergency power source, utilizing power from connected batteries during a grid failure. The methodology incorporates an interleaved topology and a multi-stage constant current (MSCC) charging method controlled by a fuzzy logic controller (FLC). Experimental results show the interleaved operation successfully increased power capacity up to 1.1 kW, achieving an average efficiency of 93.44%. A distinctive feature of the result is the reduction of the output current ripple by 47.7% down to 0.92%. This is explained by the ripple-cancellation effect inherent to the interleaved design, which is a key feature for preserving long-term battery health. Furthermore, the MSCC method achieved a 13.7% reduction in execution time compared to the conventional constant current-constant voltage (CC-CV) method, with a total charging duration of 66.8 minutes. This validated prototype successfully demonstrated a seamless and automatic emergency mode transition during a power failure, directly answering the BSS reliability challenge. The prototype also confirmed its bidirectional functionality and seamless mode transition from standard charging to emergency power supply mode. The scope of this research provides a practical and high-performance integrated solution for BSS, effectively addressing vulnerability issues by improving reliability and charging time efficiency, ensuring continuous service.

The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Affordable and clean energy
Openalex Percentile: Top 48%
Advanced Battery Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.