Spatial distribution of electron temperature and density in argon RF-biased ICP with non-quasi-neutrality effects

Two-dimensional horizontal distributions of electron temperature and density in argon inductively coupled plasma (ICP) with an applied radio frequency bias were obtained using optical emission spectroscopy (OES) combined with a spectral tomography algorithm. Additionally, Langmuir probe measurements were conducted along the diameter of the chamber to determine the spatial distributions of electron and ion densities. The results revealed a significant deviation from the assumption of quasi-neutrality near the chamber center at a height of 12 mm above the substrate. Based on this observation, the Ar collisional-radiative model results obtained from OES were recalculated under the conditions of 1 Pa discharge pressure, 600 W ICP power, and 100 W bias power, with modifications to account for the observed deviation from quasi-neutrality.

Publication Details

Journal
Tokyo Tech Research Repository (Tokyo Institute of Technology)
Published
2025-10-15
Primary Topic
Plasma Diagnostics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spatial distribution of electron temperature and density in argon RF-biased ICP with non-quasi-neutrality effects

Tokyo Tech Research Repository (Tokyo Institute of Technology)
Plasma Diagnostics and Applications
article

Spatial distribution of electron temperature and density in argon RF-biased ICP with non-quasi-neutrality effects

article en

Abstract

Two-dimensional horizontal distributions of electron temperature and density in argon inductively coupled plasma (ICP) with an applied radio frequency bias were obtained using optical emission spectroscopy (OES) combined with a spectral tomography algorithm. Additionally, Langmuir probe measurements were conducted along the diameter of the chamber to determine the spatial distributions of electron and ion densities. The results revealed a significant deviation from the assumption of quasi-neutrality near the chamber center at a height of 12 mm above the substrate. Based on this observation, the Ar collisional-radiative model results obtained from OES were recalculated under the conditions of 1 Pa discharge pressure, 600 W ICP power, and 100 W bias power, with modifications to account for the observed deviation from quasi-neutrality.

Tokyo Tech Research Repository (Tokyo Institute of Technology)
Openalex Percentile: Top 44%
Plasma Diagnostics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.