LOS RETOS DEL MONITOREO AMBIENTAL DEL COMPLEJO INTEGRADO DE RECICLAJE EN EL DISTRITO FEDERAL

The Federal District Integrated Recycling Complex (CIR-DF) contributes significantly to reducing the environmental impact of the waste produced by the metropolis of Brasilia, as it provides for the recycling of materials that would otherwise be taken to landfills and employs around 450 collectors. That said, this work sought to monitor the air quality of the CIR/DF shed spaces, checking the concentration of CO2, temperature, and humidity, in the period of intense heat and drought, relating the data with measures of adaptive comfort in order to contribute with space management. The results showed that the CO2 concentration is below 3,900 ppm in 48 hours per week indicated by NR 15 from 2022. The temperatures verified between the six monitored days are, for the most part, below 50 % of the comfort zone and the humidity data are also below the 40 % limit indicated by NR 17 from 2022. Thus, the Complex faces challenges related to the internal environmental comfort of the sheds, which can be improved by applying strategies for air renewal that are more appropriate to the location.

Publication Details

Journal
DSpace (Federal University of Santa Catarina)
Published
2024-10-31
Primary Topic
Urban Arborization and Environmental Studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

LOS RETOS DEL MONITOREO AMBIENTAL DEL COMPLEJO INTEGRADO DE RECICLAJE EN EL DISTRITO FEDERAL

DSpace (Federal University of Santa Catarina)
Urban Arborization and Environmental Studies
article

LOS RETOS DEL MONITOREO AMBIENTAL DEL COMPLEJO INTEGRADO DE RECICLAJE EN EL DISTRITO FEDERAL

article en

Abstract

The Federal District Integrated Recycling Complex (CIR-DF) contributes significantly to reducing the environmental impact of the waste produced by the metropolis of Brasilia, as it provides for the recycling of materials that would otherwise be taken to landfills and employs around 450 collectors. That said, this work sought to monitor the air quality of the CIR/DF shed spaces, checking the concentration of CO2, temperature, and humidity, in the period of intense heat and drought, relating the data with measures of adaptive comfort in order to contribute with space management. The results showed that the CO2 concentration is below 3,900 ppm in 48 hours per week indicated by NR 15 from 2022. The temperatures verified between the six monitored days are, for the most part, below 50 % of the comfort zone and the humidity data are also below the 40 % limit indicated by NR 17 from 2022. Thus, the Complex faces challenges related to the internal environmental comfort of the sheds, which can be improved by applying strategies for air renewal that are more appropriate to the location.

DSpace (Federal University of Santa Catarina)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico
Sustainable cities and communities
Openalex Percentile: Top 31%
Urban Arborization and Environmental Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.