Modified unipolar return pulsed field ablation in ventricular myocardium

BACKGROUND: Various pulsed field ablation (PFA) parameters have been proposed to improve lesion depth. This study evaluated a modified unipolar return PFA system to create deep lesions in healthy and infarcted ventricular myocardia. METHODS: Numerical modeling was used to compare a modified unipolar return PFA system configuration with a conventional unipolar return (skin patch). We then performed ablation in 14 swine (5 with chronic myocardial infarction and 9 healthy). PFA lesions were created in the left ventricle using a focal catheter (4-mm tip) with a return electrode positioned in the inferior vena cava (biphasic, microsecond pulses of 1300 and 1500 V, 1–16 trains). Electroanatomical mapping guided ablation and lesion localization on magnetic resonance imaging were performed 48 hours post-ablation in the infarcted group and at 1 day, 7 days, and 6 weeks post-ablation in the healthy group. RESULTS: Numerical modeling demonstrated that the modified unipolar return PFA system produced deeper lesions with reduced variability compared with the skin patch. In healthy pigs (n=35 lesions), depths of 6.8±1.8 mm and widths of 11.5±4.7 mm were achieved with 8 pulse trains. Depths of 8.2±2.8 mm and widths of 14.0±4.7 mm were achieved with 16 trains. The maximum lesion depths were 8.8 and 11.6 mm for 8 and 16 trains, respectively. In the infarcted cohort (n=22 lesions), all lesions applied to scar tissue penetrated through fibrotic regions, with epicardial involvement observed in 57% of lesions. CONCLUSIONS: The modified unipolar return PFA system effectively creates large lesions and can achieve transmurality in healthy and infarcted animals. Compared with conventional unipolar, it may offer greater lesion depth, width, and consistency. GRAPHIC ABSTRACT: A graphic abstract is available for this article.

Publication Details

Journal
DiRROS repository (University of Maribor)
Published
2025-10-24
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modified unipolar return pulsed field ablation in ventricular myocardium

DiRROS repository (University of Maribor)
Cardiac Arrhythmias and Treatments
article

Modified unipolar return pulsed field ablation in ventricular myocardium

article en

Abstract

BACKGROUND: Various pulsed field ablation (PFA) parameters have been proposed to improve lesion depth. This study evaluated a modified unipolar return PFA system to create deep lesions in healthy and infarcted ventricular myocardia. METHODS: Numerical modeling was used to compare a modified unipolar return PFA system configuration with a conventional unipolar return (skin patch). We then performed ablation in 14 swine (5 with chronic myocardial infarction and 9 healthy). PFA lesions were created in the left ventricle using a focal catheter (4-mm tip) with a return electrode positioned in the inferior vena cava (biphasic, microsecond pulses of 1300 and 1500 V, 1–16 trains). Electroanatomical mapping guided ablation and lesion localization on magnetic resonance imaging were performed 48 hours post-ablation in the infarcted group and at 1 day, 7 days, and 6 weeks post-ablation in the healthy group. RESULTS: Numerical modeling demonstrated that the modified unipolar return PFA system produced deeper lesions with reduced variability compared with the skin patch. In healthy pigs (n=35 lesions), depths of 6.8±1.8 mm and widths of 11.5±4.7 mm were achieved with 8 pulse trains. Depths of 8.2±2.8 mm and widths of 14.0±4.7 mm were achieved with 16 trains. The maximum lesion depths were 8.8 and 11.6 mm for 8 and 16 trains, respectively. In the infarcted cohort (n=22 lesions), all lesions applied to scar tissue penetrated through fibrotic regions, with epicardial involvement observed in 57% of lesions. CONCLUSIONS: The modified unipolar return PFA system effectively creates large lesions and can achieve transmurality in healthy and infarcted animals. Compared with conventional unipolar, it may offer greater lesion depth, width, and consistency. GRAPHIC ABSTRACT: A graphic abstract is available for this article.

DiRROS repository (University of Maribor)
Openalex Percentile: Top 33%
Cardiac Arrhythmias and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Modified unipolar return pulsed field ablation in ventricular myocardium · DiRROS repository (University of Maribor) (2025) | TGRS Research Map | TGRS