Eficácia e Segurança a 3 Anos do Dispositivo de Drenagem Posterior PAUL

INTRODUCTION: PAUL glaucoma implant is a non-valved posterior drainage device with a smaller lumen tube compared with classical alternatives. This study aimed to determine the 3-year efficacy and safety of the PAUL glaucoma implant.METHODS: Retrospective cohort study. Consecutive patients implanted with a PAUL Glaucoma Implant between December 2018 and August 2020, with a minimum follow-up period of 36 months, were included. The clinical data were acquired from the patients' records. The primary outcome was the reduction in intraocular pressure (IOP) at 36 months, with surgical success defined as ≤18 mmHg and >5 mmHg plus ≥30% drop in IOP from baseline. Failure was defined as not reaching the criteria for success for two consecutive observations after 3 months of follow-up, need for surgical intervention, or significant vision loss. Safety outcomes were also analyzed. A standardized surgical protocol was followed in all cases, which included augmentation with mitomycin C (0.4 mg/mL) and tube ligation with a polyglactin suture.RESULTS: A total of 27 eyes from 23 patients met the inclusion criteria. Both adult and pediatric forms of glaucoma were included. The mean age at the time of surgery was 36.1±27.5 (5 months - 76 years) years. Two-thirds (n=18) had a history of previous glaucoma surgery. IOP showed a statistically significant reduction at month 36 compared to baseline IOP [preoperative IOP: 30.4±10.5 vs postoperative M36 IOP: 13.7±4.7 mmHg; p<0.001]. Surgical success was achieved in 66.6% of cases at 36 months. There was also a statistically significant reduction in preoperative medications from 2.8±1.4 to 1.0±0.9 (p<0.001). During the follow-up period, persistent hypotony requiring surgical intervention was observed in 1 patient. Revision surgery was necessary in 5 patients (18.5%).CONCLUSION: The PAUL glaucoma implant is a novel posterior drainage device that shows efficacy and acceptable safety in the long-term treatment of refractory glaucoma.

Publication Details

Journal
Scientific Repository of Open Access of Portugal (RCAAP)
Published
2025-11-29
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Eficácia e Segurança a 3 Anos do Dispositivo de Drenagem Posterior PAUL

Scientific Repository of Open Access of Portugal (RCAAP)
Glaucoma and retinal disorders
article

Eficácia e Segurança a 3 Anos do Dispositivo de Drenagem Posterior PAUL

article en

Abstract

INTRODUCTION: PAUL glaucoma implant is a non-valved posterior drainage device with a smaller lumen tube compared with classical alternatives. This study aimed to determine the 3-year efficacy and safety of the PAUL glaucoma implant.METHODS: Retrospective cohort study. Consecutive patients implanted with a PAUL Glaucoma Implant between December 2018 and August 2020, with a minimum follow-up period of 36 months, were included. The clinical data were acquired from the patients' records. The primary outcome was the reduction in intraocular pressure (IOP) at 36 months, with surgical success defined as ≤18 mmHg and >5 mmHg plus ≥30% drop in IOP from baseline. Failure was defined as not reaching the criteria for success for two consecutive observations after 3 months of follow-up, need for surgical intervention, or significant vision loss. Safety outcomes were also analyzed. A standardized surgical protocol was followed in all cases, which included augmentation with mitomycin C (0.4 mg/mL) and tube ligation with a polyglactin suture.RESULTS: A total of 27 eyes from 23 patients met the inclusion criteria. Both adult and pediatric forms of glaucoma were included. The mean age at the time of surgery was 36.1±27.5 (5 months - 76 years) years. Two-thirds (n=18) had a history of previous glaucoma surgery. IOP showed a statistically significant reduction at month 36 compared to baseline IOP [preoperative IOP: 30.4±10.5 vs postoperative M36 IOP: 13.7±4.7 mmHg; p<0.001]. Surgical success was achieved in 66.6% of cases at 36 months. There was also a statistically significant reduction in preoperative medications from 2.8±1.4 to 1.0±0.9 (p<0.001). During the follow-up period, persistent hypotony requiring surgical intervention was observed in 1 patient. Revision surgery was necessary in 5 patients (18.5%).CONCLUSION: The PAUL glaucoma implant is a novel posterior drainage device that shows efficacy and acceptable safety in the long-term treatment of refractory glaucoma.

Scientific Repository of Open Access of Portugal (RCAAP)
Good health and well-being
Openalex Percentile: Top 32%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.