Environmental evaluation of residential heating

The purpose of the study is to evaluate the environmental performance of two systems for space heating and hot water provision in a residential building. In both cases, a ground-source heat pump is used. In the baseline system, the heat pump is driven by electrical power from the grid. In the alternative system, photovoltaic thermal collectors are integrated into the building for domestic hot water preparation and the production of electricity. Excess heat produced in the summer is introduced to the borehole and extracted later, in the cooler part of the year. Environmental benchmarking of the two systems was conducted using the Life Cycle Assessment method. A cradle-to-grave approach was applied, taking into account all life cycle stages of the system and its operation over 20 years. Results show that the alternative system yields significantly lower impacts in terms of Global Warming Potential (36% decrease) and Resources (36% decrease). In terms of Human Health, the decrease is minor (6%). However, in terms of Ecosystem, the alternative system shows a 47% higher impact than the baseline system. This increase is primarily attributed to the additional components required in the alternative configuration.

Publication Details

Journal
DiRROS repository (University of Maribor)
Published
2025-11-04
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Environmental evaluation of residential heating

DiRROS repository (University of Maribor)
Geothermal Energy Systems and Applications
article

Environmental evaluation of residential heating

article en

Abstract

The purpose of the study is to evaluate the environmental performance of two systems for space heating and hot water provision in a residential building. In both cases, a ground-source heat pump is used. In the baseline system, the heat pump is driven by electrical power from the grid. In the alternative system, photovoltaic thermal collectors are integrated into the building for domestic hot water preparation and the production of electricity. Excess heat produced in the summer is introduced to the borehole and extracted later, in the cooler part of the year. Environmental benchmarking of the two systems was conducted using the Life Cycle Assessment method. A cradle-to-grave approach was applied, taking into account all life cycle stages of the system and its operation over 20 years. Results show that the alternative system yields significantly lower impacts in terms of Global Warming Potential (36% decrease) and Resources (36% decrease). In terms of Human Health, the decrease is minor (6%). However, in terms of Ecosystem, the alternative system shows a 47% higher impact than the baseline system. This increase is primarily attributed to the additional components required in the alternative configuration.

DiRROS repository (University of Maribor)
Responsible consumption and production
Openalex Percentile: Top 56%
Geothermal Energy Systems and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Environmental evaluation of residential heating · DiRROS repository (University of Maribor) (2025) | TGRS Research Map | TGRS